Induction Machine Measurement
Measuring the values of asynchronous machine variables.
Description
The Induction Machine Measurement block outputs the variable values received from the Induction Machine Squirrel Cage block. The input of the Induction Machine Measurement block is connected to the output port of the asynchronous machine block.
The Output parameter determines the value to be output. Depending on the selected value, the Induction Machine Measurement unit:
-
Directly outputs the value of the element in the input signal vector
Or
-
Calculates the value in relative units based on other elements in the input vector.
The Induction Machine Measurement block outputs the value of the asynchronous machine variable according to the expressions given in the table. For example, when the Output parameter is set to Stator d-axis voltage
, the block outputs directly the value of the v_ds_pu
element in the input vector. However, when the Output parameter is set to Slip
, the block calculates the slip value by subtracting the value of the velocity_pu
element from 1.
Output value | Value of parameter Output | Calculation of output value |
---|---|---|
Electromagnetic torque |
Electrical torque |
torque_pu |
Rotor speed |
Rotor velocity |
velocity_pu |
Stator d-axis voltage |
Stator d-axis voltage |
v_ds_pu |
Stator q-axis voltage |
Stator q-axis voltage |
v_qs_pu |
Stator zero-sequence voltage |
Stator zero-sequence voltage |
v_0s_pu |
Stator d-axis current |
Stator d-axis current |
i_ds_pu |
Stator q-axis current |
Stator q-axis current |
i_qs_pu |
Stator zero-sequence stator current |
Stator zero-sequence current |
i_0s_pu |
Slip |
Slip |
slip |
Total power |
Apparent power |
|
Active power |
Real power |
|
Reactive power |
Reactive power |
|
Terminal voltage |
Terminal voltage |
|
Terminal current |
Terminal current |
|
Current and voltage phase angle, rad |
Power factor angle (rad) |
|
Power factor |
Power factor |
|
Parameters
Output - measurement
Electrical torque (By default)
| Rotor velocity
| Stator d-axis voltage
| Stator q-axis voltage
| Stator zero-sequence voltage
| Stator d-axis current
| Stator q-axis current
| Stator zero-sequence current
| Slip
| Apparent power
| Real power
| Reactive power
| Terminal voltage
| Power factor angle
| Power factor angle
Output parameter of the asynchronous machine. It has the following options:
-
Electrical torque
. -
`Rotor velocity
-
`Stator d-axis voltage
-
`Stator q-axis voltage
-
`Stator zero-sequence voltage
-
`Stator d-axis current
-
`Stator q-axis current
-
`Stator zero-sequence current
-
`Slip
-
Apparent power
-
`Real power
-
`Reactive power
-
Terminal voltage
-
Power factor angle
-
Power factor angle