Engee documentation

PRAGMASOFT RX

Getting data from PragmaSoft Studio.

blockType: SubSystem

Path in the library:

/Interfaces/PragmaSoft/PRAGMASOFT RX

Description

To work with the block, install/update the support package. equipment.

Block PRAGMASOFT RX it is used to get data from PragmaSoft Studio.

Ports

Output

# Size — the number of bytes received
scalar

Details

No more than the value of the parameter Maximum message size. If there is more data in the operating system buffer, it will be read during the next calculation step.

Data types

UInt32

Complex numbers support

No

# Data — array of accepted bytes
vector

Details
Data types

Float64

Complex numbers support

No

Parameters

Main group

# Listening address: — IPv4 address received by the server

Details
Default value

"0.0.0.0"

Program usage name

m_ip

Tunable

No

Evaluatable

Yes

# Port Listening: — server port

Details
Default value

7901

Program usage name

m_port

Tunable

No

Evaluatable

Yes

# Maximum message size: — the maximum possible length of the received data

Details
Default value

4080

Program usage name

m_max_mes_size

Tunable

No

Evaluatable

Yes