Engee documentation

BA-IS-XX DAC

Sending samples to ADC channels of the RITMeX BA-IS-XX I/O module.

blockType: CFunction

Path in the library:

/RITM/RITMeX BA-IS-XX/BA-IS-XX DAC ADC/BA-IS-XX DAC

Description

Block BA-IS-XX DAC is used to send samples to ADC channels of the RITMeX BA-IS-XX I/O module.

Ports

Input

# dac — data to be sent to analogue outputs
vector

Details

Can be an array depending on the value of the Number of words parameter.

Data types

Float64.

Complex numbers support

No

Parameters

Параметры

# Номер модуля: — unique module identification
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8

Details

Used to uniquely identify a module when more than one I/O module of the same type is installed in the real-time machine.

Module numbers are signed on the RITM housing.

Values

1 | 2 | 3 | 4 | 5 | 6 | 7 | 8

Default value

1

Program usage name

m_module_idx

Tunable

No

Evaluatable

Yes

# Количество каналов: — number of analogue input channels
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16

Details
Values

1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16

Default value

1

Program usage name

m_dac_amount

Tunable

No

Evaluatable

Yes

# Шаг расчёта, с: — calculation step in seconds at which the counts are output to analogue outputs

Details
Default value

-1

Program usage name

m_sample_time

Tunable

No

Evaluatable

Yes