Engee documentation

Power (dq0, Instantaneous)

Page in progress.

Three-phase instantaneous active and reactive power.

power three phase dq0 instantaneous

Description

The Power (dq0, Instantaneous) block calculates three-phase instantaneous active and reactive powers from a periodic set of three-phase voltages and currents expressed in the coordinate system .

The calculations are performed using the following formulae:




The Vdq0 and Idq0 inputs (direct axis, quadrature axis and zero-sequence components) of three-phase voltage and current are normally connected to the outputs of the abc-to-dq0 conversion unit. According to these formulae, the current flowing in the RL circuit produces a positive value of P and a positive value of Q. The calculated instantaneous reactive power is accurate only for balanced and harmonic-free three-phase voltages and currents.

Ports

Input

# Vdq0 — voltage signal expressed in the reference frame
scalar

Details

Voltage signal expressed in the reference frame .

Data types

Float64.

Complex numbers support

No

# Idq0 — current signal expressed in the reference frame
scalar

Details

Current signal expressed in the reference frame .

Data types

Float64.

Complex numbers support

No

Output

# P — three-phase instantaneous active power
scalar

Details

Three-phase instantaneous active power P, in W.

Data types

Float64.

Complex numbers support

No

# Q — three-phase instantaneous reactive power
scalar

Details

Three-phase instantaneous reactive power Q, in VAR.

Data types

Float64.

Complex numbers support

No

Parameters

None.

Additional options

C code generation: Yes