Absolute Reference (G)
Reference point: zero absolute temperature and pressure.
This unit is not recommended for usage. |
blockType: AcausalFoundation.Gas.Elements.Reference
Path in the library:
|
Description
The unit Absolute Reference (G) is a reference point for pressure and temperature in the gas network. At port A the pressure and temperature are zero.
In contrast to other domains, where each topologically separate circuit within a domain must contain at least one reference block, there is no such requirement in gas networks.
The purpose of the Absolute Reference (G) block is to provide a reference for Pressure & Temperature Sensor (G). To measure the absolute pressure and absolute temperature of a node, connect that node to port A of the Pressure & Temperature Sensor (G) block. Connect port B of the Pressure & Temperature Sensor (G) unit to the Absolute Reference (G) unit.
If you use the Absolute Reference (G) unit more than once on the same gas network, it will cause simulations because the gas pressure and temperature cannot be set to absolute zero.
Using this block is not recommended. Instead, take absolute measurements using the Pressure & Temperature Sensor (G) block by setting the Measurement type parameters to `Absolute'.