GP-AD-24 DAC-single
Page in progress. |
Setting values of one of the analogue outputs of the RITMeX GP-AD-24 I/O module.
Description
The block is used to set the value of one of the analogue outputs of the RITMeX GP-AD-24 I/O module.
Parameters
Module number -
unique module identification
1 (by default)
| 2
| 3
| 4
| 5
| 6
| 7
| 8
Details
Used when more than one I/O module of the same type is installed in a real-time machine.
The module numbers are signed on the case of the CPM "RITM".
Output type -
setting the type of analogue outputs of the module
Voltage (by default)
| Current 0-20 mA
| Current 4-20 mA
Channel number -
Setting the number of the engaged analogue output of the module
1 (By default)
| 2 | `3 | `4 | `5 | `6 | `7 | `8 | `9 | `10 | `11 | `12 | `13 | `14 | `15 ` | `16
| 17
| 18
| 19
| 20
| 21
| 22
| 23
| 24
| 25
| 26
| 27
| 28
| 29
| 30
| 31
| 32
Details
The contacts are connected according to the diagram in the article Purpose of GP-AD-24 pins. |
Calculation Step -
calculation step in seconds for sending samples to the DAC from the real-time application
`-1 (By default).