Engee documentation

MI-EL-45 RtPut

Writing data to the subaddress register.

blockType: CFunction

Path in the library:

/RITM/RITMeX MI-EL-45/MI-EL-45 RtPut

Description

To work with the block, install/update the support package RITM blocks.

Block MI-EL-45 RtPut it is used to write data to the subaddress register.

Ports

Input

# EI subaddress — subaddress of the data recording endpoint
scalar

Details
Data types

Float64.

Complex numbers support

No

# data — array of 32 elements to be written to the subaddress of the terminal device
vector

Details
Data types

UInt16.

Complex numbers support

No

Parameters

Main group

# Номер канала: — MKIO channel number
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8

Details

If more than one module is installed in the machine, end-to-end channel numbering is applied.

Values

1 | 2 | 3 | 4 | 5 | 6 | 7 | 8

Default value

1

Program usage name

m_chNum

Tunable

No

Evaluatable

Yes

# Шаг расчёта, с: — the calculation step with which data is written to the address register of the terminal device

Details

Defines the sampling period of the block (in seconds) with which the operation of writing an array of data to the register of the selected subaddress of the terminal device is initiated. Too small a step value can lead to repeated recording before the end of the previous exchange cycle and create an excessive load on the MCIO channel.

Default value

-1

Program usage name

m_smplT

Tunable

No

Evaluatable