Vapor Quality Sensor (2P)

Measurement of the vapor fraction in two-phase liquids.

blockType: AcausalFoundation.TwoPhaseFluid.Sensors.VaporQuality

Path in the library:

/Physical Modeling/Fundamental/Two Phase Fluid/Sensors/Vapor Quality Sensor (2P)

Description

Block Vapor Quality Sensor (2P) measures the proportion of steam in a two-phase liquid. This proportion can be expressed in mass (degree of dryness) or in volume (volume vapor content). Use the parameter Vapor fraction specification to specify the way to express the fraction of steam.

The unit measures the degree of dryness in port A and transmits its value as a scalar signal to port X. The value of the vapor fraction may vary from 0 for clean liquid up to 1 for pure steam. The intermediate values correspond to two-phase mixtures. The sensor is ideal, meaning there is no exchange of mass and energy.

If the pressure exceeds the critical point for the liquid, the vapor and liquid cease to exist, and the measurement becomes uncertain. In this case, the block outputs the value −1, which is used to indicate a critical or supercritical condition.

Ports

Conserving

# A — sensor input
two-phase liquid

Details

Non-directional two-phase liquid port. Connect this port to the node in the two-phase liquid network where you want to measure the vapor fraction.

Program usage name

port

Output

# X — degree of dryness, dimensionless
scalar

Details

Signal output port for measuring the vapor fraction in a two-phase liquid. Use the parameter Vapor fraction specification to select the measurement type.

Data types

Float64

Complex numbers support

No

Parameters

Parameters

# Vapor fraction specification — the proportion of steam by mass or volume
Vapor quality | Vapor void fraction

Details

The type of measurement output to port X. Choose Vapor quality for the mass fraction of steam in a two-phase liquid. Or choose Vapor void fraction for the volume fraction of steam in a two-phase liquid. In both cases, the measurement value may vary from 0 before 1. For critical and supercritical fluids, the output value is −1.

Values

Vapor quality | Vapor void fraction

Default value

Vapor quality

Program usage name

vapor_fraction_type

Evaluatable

No