Engee documentation

SV RX

Unpacking and highlighting the values of the SV package fields.

blockType: SubSystem

Path in the library:

/Physical Modeling/Electrical/Communication Protocols/IEC 61850/Sampled Values/SV RX

Description

Block SV RX It is used for unpacking and highlighting the values of the SV package fields.

Ports

Input

# Size — data size
scalar

Details

The size of the data segment received from the block RITM-ETH-RAW RX.

Data types

UInt32

Complex numbers support

No

# Data — data
vector

Details

The packet data segment received from the block RITM-ETH-RAW RX.

Data types

UInt8

Complex numbers support

No

Output

# Fields — the bus containing all the fields of the SV frame
the tire

Details

To select the value of a specific field or set of fields, use the block Bus Selector the base library.

Data types

bus

Complex numbers support

No

Parameters

Main group

# Enable scaling — scaling of analog signals

Details

Select this option to enable scaling of analog signals during decompression of the frame.

Default value

true (switched on)

Program usage name

enable_scaling

Evaluatable

Yes

# Signals types — vector of analog signal types

Details

A vector that defines the scaling factors to be applied to analog signals. The vector must contain 8 elements with values "i" or "v". If The -th element of the vector is set equal to "i", then for -The analog signal will be applied Currents factor And if "v" Then Voltages factor.

Dependencies

To use this option, check the box Enable scaling.

Default value

["i", "i", "i", "i", "v", "v", "v", "v"]

Program usage name

signals_types

Evaluatable

Yes

# Currents factor — scaling factor for current signals

Details

Scaling factor for current signals.

Dependencies

To use this option, check the box Enable scaling.

Default value

0.001

Program usage name

currents_factor

Evaluatable

Yes

# Voltages factor — scaling factor for voltage signals

Details

Scaling factor for voltage signals.

Dependencies

To use this option, check the box Enable scaling.

Default value

0.01

Program usage name

voltages_factor

Evaluatable

Yes

Sample time

# Sample time — calculation step

Details

The calculation step is in seconds.

Default value

0.000250

Program usage name

sample_time

Evaluatable

Yes