Liquid Properties Sensor (IL)
Measurement of density, volumetric modulus of elasticity and the proportion of air in the network of an isothermal liquid.
blockType: AcausalFoundation.IsothermalLiquid.Sensors.LiquidProperties
Path in the library:
|
Description
Block Liquid Properties Sensor (IL) It is an ideal sensor that allows you to measure the density of the mixture, the volumetric modulus of elasticity and the proportion of air in the network of an isothermal liquid. There is no mass flow through the sensor.
The unit measures these properties on a node connected to port A. All measurements are made relative to absolute zero.
The block icon changes depending on the value of the parameters Density, Isothermal bulk modulus and Fraction of air that is entrained.
Ports
Output
rho — density, kg/m3
scalar
Signal output port for measuring the density of an isothermal liquid mixture.
Dependencies
To use this port, select the Density checkbox.
beta — volumetric modulus of elasticity, Pa
scalar
Signal output port for measuring the volumetric modulus of elasticity of an isothermal liquid mixture.
Dependencies
To use this port, select the Isothermal bulk modulus checkbox.
theta — air share
scalar
Signal output port for measuring the proportion of entrained (undissolved) air:
.
Value 1 means that there is no dissolved air. Value 0 means that all the air is dissolved.
Dependencies
To use this port, check the box Fraction of air that is entrained.
Parameters
Density — visibility of the output port for density measurement
enabled (by default) | turned off
Checking this box opens the rho output port, which allows you to measure the density of the liquid.
Isothermal bulk modulus — visibility of the output port for measuring the volumetric modulus of elasticity
enabled | disabled (by default)
Setting this check box opens the beta output port for measuring the volumetric modulus of elasticity of an isothermal liquid mixture.
Fraction of air that is entrained — visibility of the output port for measuring the fraction of air
enabled | disabled (by default)
Setting this check box opens the theta output port for measuring the proportion of entrained (undissolved) air.