Engee documentation

Flow Rate Sensor (MA)

Measurement of mass, volume and energy flow in a wet air network.

blockType: AcausalFoundation.MoistAir.Sensors.FlowRate

Path in the library:

/Physical Modeling/Fundamental/Moist Air/Sensors/Flow Rate Sensor (MA)

Description

The Flow Rate Sensor (MA) unit is an ideal sensor that measures mass flow rate, energy flow rate and volume flow rate in a humid air network. Pressure, temperature, specific humidity or mass fraction of impurity gases do not change on the sensor.

The unit is connected in series with the component to be measured.

The mutual orientation of the ports A and B sets the sign of the measurement. The sign is positive if the flow is from port A to port B and vice versa.

Switching the connections to the ports reverses the sign of the measurement.

Five ports are available to output measurement data:

  • Port M outputs mass flow rate.

  • The V port outputs the volumetric flow rate.

  • Port φ outputs the energy flow rate.

  • Port Mw outputs the mass flow rate of water vapour.

  • Port Mg outputs the mass flow rate of impure gases.

These ports are displayed on the unit icon depending on the unit settings. Adjust the unit parameters to display only those ports that are required for measurements in a particular model.

Ports

Conserving

# A — sensor input
`humid air

Details

Humid air port, corresponds to the sensor inlet. The flow rate is positive when air flows from port A to port B.

Program usage name

inlet

# B — sensor input
`humid air

Details

Humid air port, corresponds to the sensor input. The flow rate is positive when air flows from port A to port B.

Program usage name

outlet

Output

# M — mass flow rate, kg/s
scalar

Details

Output port for mass flow measurement.

Dependencies

To use this port, select the checkbox Mass flow rate.

Data types

Float64.

Complex numbers support

No

# φ — energy consumption, W
scalar

Details

Output port for measuring energy consumption.

Dependencies

To use this port, tick the checkbox Energy flow rate.

Data types

Float64.

Complex numbers support

No

# V — volumetric flow rate, m3/sec
scalar

Details

Output port for volumetric flow measurement.

Dependencies

To use this port, select the checkbox Volumetric flow rate.

Data types

Float64.

Complex numbers support

No

# Mw — mass flow rate of water vapour, kg/sec
scalar

Details

Output port for measuring the mass flow rate of water vapour.

Dependencies

To use this port, select the checkbox Water vapor mass flow rate.

Data types

Float64.

Complex numbers support

No

# Mg — mass flow rate of impurity gases, kg/sec
scalar

Details

Output port for measuring the mass flow rate of impurity gases.

Dependencies

To use this port, select the checkbox Trace gas mass flow rate.

Data types

Float64.

Complex numbers support

No

Parameters

Parameters

# Mass flow rate — switching on the output port for mass flow measurement

Details

Select this checkbox to have the sensor measure mass flow rate.

Selecting this checkbox opens the M output port.

Default value

true (switched on)

Program usage name

measure_mass_flow_rate

Evaluatable

No

# Volumetric flow rate — switching on the output port for volumetric flow measurement

Details

Select this checkbox to have the sensor measure volumetric flow rate.

Selecting this checkbox opens the V output port.

Default value

false (switched off)

Program usage name

measure_volumetric_flow_rate

Evaluatable

No

# Volumetric flow measurement conditions — conditions for volumetric flow measurement
Actual conditions | Standard conditions

Details

Select whether the sensor calculates the volumetric flow rate under actual operating conditions or at standard pressure, temperature, and relative humidity:

  • Actual conditions - the sensor calculates the volumetric flow rate using the density of moist air under actual system operating conditions.

  • Standard conditions - the sensor calculates the volumetric flow rate using the density of moist air under standard conditions. If this option is selected, additional parameters are available to set standard pressure, temperature, and relative humidity.

Dependencies

To use this option, select the checkbox for the parameters Volumetric flow rate.

Values

Actual conditions | Standard conditions

Default value

Actual conditions

Program usage name

volumetric_flow_conditions

Evaluatable

No

# Standard pressure — Humid air pressure at standard conditions
Pa | GPa | MPa | atm | bar | kPa | ksi | psi | uPa | kbar

Details

Humid air pressure at standard conditions.

Dependencies

To use this parameter, select the check box for the parameter Volumetric flow rate, and set the value for the parameter Volumetric flow measurement conditions to Standard conditions.

Units

Pa | GPa | MPa | atm | bar | kPa | ksi | psi | uPa | kbar

Default value

0.101325 MPa

Program usage name

p_standard

Evaluatable

Yes

# Standard temperature — Humid air temperature at standard conditions
K | degC | degF | degR | deltaK | deltadegC | deltadegF | deltadegR

Details

Humid air temperature at standard conditions.

Dependencies

To use this parameter, select the check box for the Volumetric flow rate parameter and set the Volumetric flow measurement conditions parameter to Standard conditions.

Units

K | degC | degF | degR | deltaK | deltadegC | deltadegF | deltadegR

Default value

20.0 degC

Program usage name

T_standard

Evaluatable

Yes

# Standard relative humidity — relative humidity at standard conditions

Details

Relative air humidity at standard conditions.

Dependencies

To use this parameter, select the check box for the parameter Volumetric flow rate, and set the parameter Volumetric flow measurement conditions to Standard conditions.

Default value

0.65

Program usage name

RH_standard

Evaluatable

Yes

# Energy flow rate — switching on the output port for measuring energy consumption

Details

Select this check box to have the sensor measure energy consumption.

Selecting this check box opens the φ output port.

Default value

true (switched on)

Program usage name

measure_energy_flow_rate

Evaluatable

No

# Water vapor mass flow rate — switching on the output port for measuring the mass flow rate of water vapour

Details

Select this checkbox to have the sensor measure the mass flow rate of water vapour.

Checking this box opens the Mw output port.

Default value

false (switched off)

Program usage name

measure_water_vapor_flow_rate

Evaluatable

No

# Trace gas mass flow rate — switching on the output port for measuring the mass flow rate of impurity gases

Details

Select this checkbox to have the sensor measure the mass flow rate of impure gases.

Checking this box opens the Mg output port.

Default value

false (switched off)

Program usage name

measure_trace_gas_flow

Evaluatable

No