Engee documentation

Flow Rate Sensor (MA)

Measurement of mass, volume and energy consumption in the humid air network.

blockType: AcausalFoundation.MoistAir.Sensors.FlowRate

Path in the library:

/Physical Modeling/Fundamental/Moist Air/Sensors/Flow Rate Sensor (MA)

Description

Block Flow Rate Sensor (MA) It is an ideal sensor that measures mass flow, energy consumption and volume flow in the humid air network. The pressure, temperature, specific humidity or mass fraction of impurity gases on the sensor do not change.

The unit is connected in series with the measured component.

The mutual orientation of ports A and B sets the measurement sign. The sign is positive if the flow goes from port A to port B, and vice versa.

Switching connections to ports changes the sign of the measurement to the opposite.

Five ports are available for the output of measurement data:

  • Port M outputs the mass flow rate.

  • Port V outputs the volumetric flow rate.

  • Port φ displays the power consumption value.

  • The Mw port displays the mass flow of water vapor.

  • Port Mg displays the value of the mass flow of impurity gases.

  • Port Md displays the value of the mass flow of water droplets.

These ports are displayed on the block icon depending on the block settings. Configure the parameters of the unit to display only those ports that are necessary for measurements in a particular model.

Ports

Output

# V — volumetric flow rate, m3/s
scalar

Details

Output port for volume flow measurement.

Dependencies

To use this port, check the box Volumetric flow rate.

Data types

Float64

Complex numbers support

No

# Mw — mass flow rate of water vapor, kg/s
scalar

Details

An output port for measuring the mass flow of water vapor.

Dependencies

To use this port, check the box Water vapor mass flow rate.

Data types

Float64

Complex numbers support

No

# Mg — mass consumption of impurity gases, kg/s
scalar

Details

An output port for measuring the mass flow of impurity gases.

Dependencies

To use this port, check the box Trace gas mass flow rate.

Data types

Float64

Complex numbers support

No

# φ — power consumption, W
scalar

Details

An output port for measuring energy consumption.

Dependencies

To use this port, check the box Energy flow rate.

Data types

Float64

Complex numbers support

No

# M — mass flow rate, kg/s
scalar

Details

Output port for mass flow measurement.

Dependencies

To use this port, check the box Mass flow rate (dry air, water vapor, trace gas).

Data types

Float64

Complex numbers support

No

# Md — mass flow rate of water droplets, kg/s
scalar

Details

An output port for measuring the mass flow of water droplets.

Dependencies

To use this port, check the box Water droplets mass flow rate.

Data types

Float64

Complex numbers support

No

Conserving

# A — sensor input
humid air

Details

The humid air port corresponds to the sensor inlet. The flow rate is positive if the air flows from port A to port B.

Program usage name

inlet

# B — sensor input
humid air

Details

The humid air port corresponds to the sensor input. The flow rate is positive if the air flows from port A to port B.

Program usage name

outlet

Parameters

Main

# Energy flow rate — enabling the output port to measure power consumption

Details

Select this option so that the sensor measures the energy consumption.

When this option is selected, the output port φ opens.

Default value

true (switched on)

Program usage name

measure_energy_flow_rate

Evaluatable

No

# Water droplets mass flow rate — switching on the output port for measuring the mass flow of water droplets

Details

Select this option so that the sensor measures the mass flow of water droplets.

When this option is selected, the Md output port opens.

Default value

false (switched off)

Program usage name

measure_droplets_flow_rate

Evaluatable

No

# Trace gas mass flow rate — switching on the output port for measuring the mass flow of impurity gases

Details

Select this option so that the sensor measures the mass flow of impurity gases.

When this option is selected, the Mg output port opens.

Default value

false (switched off)

Program usage name

measure_trace_gas_flow_rate

Evaluatable

No

# Volumetric flow rate — enabling the output port for volume flow measurement

Details

Select this option so that the sensor measures the volume flow.

When this option is selected, the output port V opens.

Default value

false (switched off)

Program usage name

measure_volumetric_flow_rate

Evaluatable

No

# Volumetric flow measurement conditions — conditions for measuring volume flow
Actual conditions | Standard conditions

Details

Select whether the sensor calculates the volumetric flow rate under real operating conditions or at standard pressure, temperature, and relative humidity.:

  • Actual conditions — the sensor calculates the volumetric flow rate using the density of moist air under real operating conditions of the system.

  • Standard conditions — The sensor calculates the volumetric flow rate using the density of humid air under standard conditions. If this option is selected, additional parameters become available for setting standard pressure, temperature, and relative humidity.

Dependencies

To use this option, check the box for the option Volumetric flow rate.

Values

Actual conditions | Standard conditions

Default value

Actual conditions

Program usage name

volumetric_flow_conditions

Evaluatable

No

# Standard temperature — humid air temperature under standard conditions
K | degC | degF | degR | deltaK | deltadegC | deltadegF | deltadegR

Details

Humid air temperature under standard conditions.

Dependencies

To use this option, check the box for the option Volumetric flow rate, and for the parameter Volumetric flow measurement conditions set the value Standard conditions.

Units

K | degC | degF | degR | deltaK | deltadegC | deltadegF | deltadegR

Default value

20.0 degC

Program usage name

T_standard

Evaluatable

Yes

# Mass flow rate (dry air, water vapor, trace gas) — enabling the output port for mass flow measurement

Details

Select this option so that the sensor measures the mass flow.

When this option is selected, the output port M opens.

Default value

true (switched on)

Program usage name

measure_mass_flow_rate

Evaluatable

No

# Standard pressure — humid air pressure under standard conditions
Pa | uPa | hPa | kPa | MPa | GPa | kgf/m^2 | kgf/cm^2 | kgf/mm^2 | mbar | bar | kbar | atm | ksi | psi | mmHg | inHg

Details

Humid air pressure under standard conditions.

Dependencies

To use this option, check the box for the option Volumetric flow rate, and for the parameter Volumetric flow measurement conditions set the value Standard conditions.

Units

Pa | uPa | hPa | kPa | MPa | GPa | kgf/m^2 | kgf/cm^2 | kgf/mm^2 | mbar | bar | kbar | atm | ksi | psi | mmHg | inHg

Default value

0.101325 MPa

Program usage name

p_standard

Evaluatable

Yes

# Water vapor mass flow rate — switching on the output port for measuring the mass flow of water vapor

Details

Select this option so that the sensor measures the mass flow of water vapor.

When this option is selected, the output port Mw opens.

Default value

false (switched off)

Program usage name

measure_water_vapor_flow_rate

Evaluatable

No

# Standard relative humidity — relative humidity of the air under standard conditions

Details

Relative humidity of the air under standard conditions.

Dependencies

To use this option, check the box for the option Volumetric flow rate, and for the parameter Volumetric flow measurement conditions set the value Standard conditions.

Default value

0.65

Program usage name

RH_standard

Evaluatable

Yes