Thermodynamic Properties Sensor (MA)
Measurement of specific enthalpy, density, specific heat capacity at constant pressure and specific entropy in a network of moist air.
blockType: AcausalFoundation.MoistAir.Sensors.ThermodynamicProperties
Path in the library:
|
Description
The Thermodynamic Properties Sensor (MA) unit is an ideal sensor that measures specific enthalpy, density, specific heat capacity at constant pressure and specific entropy in a network of moist air. There is no mass or energy flow through the sensor.
The unit measures these thermodynamic properties in a node connected to port A. With the Measurements based on parameters you can choose to output these measurements: normalised to the mass of the entire humid air mixture or to the mass of only dry air and gas impurities (without water vapour mass).
The specific entropy reference value used to calibrate the sensor is 0
for each component of the moist air mixture at atmospheric pressure and atmospheric temperature.
Ports
Conserving
#
A
—
sensor input
`humid air
Details
Humid air port, corresponds to the input to the sensor. Connect this port to the node in the humid air network where you want to measure the thermodynamic properties.
Program usage name |
|
Output
#
ρ
—
density, kg/m3
scalar
Details
Output port for density measurement in a wet air network.
Dependencies
To use this port, select the check box for the parameters Density.
Data types |
|
Complex numbers support |
No |
#
h
—
specific enthalpy, J/kg
scalar
Details
Signal output port for measuring specific enthalpy in a humid air network.
Dependencies
To use this port, select the check box for the parameters Enthalpy.
Data types |
|
Complex numbers support |
No |
#
cp
—
specific heat capacity at constant pressure, J/(kg⋅K)
scalar
Details
Signal output port for measuring the specific heat capacity of moist air at constant pressure.
Dependencies
To use this port, select the check box for the parameters Specific heat.
Data types |
|
Complex numbers support |
No |
#
s
—
specific entropy, J/(kg⋅K)
scalar
Details
Signal output port for measuring the specific entropy of moist air.
Dependencies
To use this port, select the checkbox for the parameters Entropy.
Data types |
|
Complex numbers support |
No |
Parameters
Parameters
#
Measurements based on —
measurement output option
Mixture air
| Dry air and trace gas
Details
Select the measurement output option: normalised to the mass of the entire moist air mixture or to the mass of dry air and gas impurities only (without moisture).
-
Mixture air
- for each thermodynamic property, the measured mass of this property in the volume of moist air is divided by the mass of the moist air mixture itself. -
Dry air and trace gas
- for each thermodynamic property, the measured mass of that property in the volume of moist air is divided by the mass of dry air and gas impurities (excluding the mass of water vapour).
Values |
|
Default value |
|
Program usage name |
|
Evaluatable |
No |
# Enthalpy — switching on the output port for specific enthalpy measurement
Details
Checking this box enables the h output port to measure the specific enthalpy of an air mixture.
Default value |
|
Program usage name |
|
Evaluatable |
No |
#
Enthalpy reference state —
select the reference state for the specific enthalpy output signal
As provided in Moist Air Properties (MA) block
| 0 degC with water as vapor
| 0 degC with water as liquid
Details
Select the reference state for the specific enthalpy output signal:
-
As provided in Moist Air Properties (MA) block
- The sensor outputs the enthalpy of the mixture based directly on the enthalpy vectors provided in the Moist Air Properties (MA) block , without corrections. This option is for informational purposes only, as library blocks use corrected values. -
0 degC with water as vapor
- The sensor outputs the enthalpy of the mixture corrected to a baseline of0
kJ/kg at0
°C. These are the values used in the library blocks and displayed in the simulation log. -
0 degC with water as liquid
- The sensor outputs the mixture enthalpy corrected so that the liquid water has an initial state of0
kJ/kg at0
°C. In this case, the enthalpy of water vapour includes the enthalpy of vaporisation or latent heat in the initial state. These are the values used in wall condensation calculations.
Dependencies
To use this parameter, select the checkbox Enthalpy.
Values |
|
Default value |
|
Program usage name |
|
Evaluatable |
No |
# Density — switching on the output port for density measurement
Details
Checking this box enables the ρ output port to measure the density of the air mixture.
Default value |
|
Program usage name |
|
Evaluatable |
No |
# Specific heat — switching on the output port for specific heat measurement
Details
Checking this box enables the cp output port to measure the specific heat capacity of an air mixture.
Default value |
|
Program usage name |
|
Evaluatable |
No |
# Entropy — switching on the output port for specific entropy measurement
Details
Checking this box enables the s output port to measure the specific entropy of the air mixture.
Default value |
|
Program usage name |
|
Evaluatable |
No |