Engee documentation

GP-ID-4x AO

Setting the values of analogue output of the RITMeX GP-ID-45 and RITMeX GP-ID-46 I/O module.

blockType: CFunction

Path in the library:

/RITM/RITMeX GP-ID-4X/GP-ID-4x AO

Description

Block GP-ID-4x AO is used to set the value of analogue output of the RITMeX GP-ID-45 and RITMeX GP-ID-46 I/O module.

Ports

Input

# IN_1 — values for digital output channels
scalar

Details

Each input takes a value that determines the state of the corresponding digital output channel of the selected hardware port (parameter Port).

Data types

Float64.

Complex numbers support

No

Parameters

Параметры

# Номер модуля: — unique module identification
1 | 2 | 3 | 4 | 5 | 6 | 7

Details

Used to uniquely identify a module when more than one I/O module of the same type is installed in a real-time machine.

Module numbers are signed on the RITM housing.

Values

1 | 2 | 3 | 4 | 5 | 6 | 7

Default value

1

Program usage name

m_module_idx

Tunable

No

Evaluatable

Yes

# Номер аналогового выхода: — analogue output channel number
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16

Details
Values

1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16

Default value

1

Program usage name

m_ao_number

Tunable

No

Evaluatable

Yes

# Тип выхода: — output type selection
Напряжение | Ток

Details
Changing the Current/Voltage mode requires physical switching of contacts according to the diagram in the article GP-ID-4X pin assignment
Values

Напряжение | Ток

Default value

Напряжение

Program usage name

m_out_type

Tunable

No

Evaluatable

Yes

# Шаг расчёта, с: — calculation step in seconds for sending samples to the DAC from the real-time application

Details
Default value

-1

Program usage name

m_sample_time

Tunable

No

Evaluatable

Yes