Engee documentation

Infinite Flow Resistance (2P)

An ideal break in the two-phase liquid network.

blockType: AcausalFoundation.TwoPhaseFluid.Elements.InfiniteFlowResistance

Path in the library:

/Physical Modeling/Fundamental/Two Phase Fluid/Elements/Infinite Flow Resistance (2P)

Description

Block Infinite Flow Resistance (2P) It is a gap in the network of a two-phase liquid. There is no mass or energy flow through it.

The thermodynamic properties are the same on both sides of the gap.

Using this unit, you can set the priority and initial target value for the pressure difference and specific internal energy between ports A and B.

Ports

Conserving

# A — a zero-cost port
two-phase liquid

Details

A two-phase liquid port where the mass flow and energy consumption are zero.

Program usage name

port_a

# B — a zero-cost port
two-phase liquid

Details

A two-phase liquid port where the mass flow and energy consumption are zero.

Program usage name

port_b