Engee documentation

Current-Controlled Current Source

A current-controlled power source.

blockType: AcausalFoundation.Electrical.Sources.CurrentControlledCurrent

Path in the library:

/Physical Modeling/Fundamental/Electrical/Sources/Current-Controlled Current Source

Description

Block Current-Controlled Current Source It is a current-controlled current source described by the following equation:

where

  • — output current;

  • — gain factor;

  • — current of the control circuit.

To use the unit, connect the + and ports on the left side of the unit (control ports) to the control current source. The arrow between these ports indicates the positive direction of the control current. The two ports on the right side of the unit (output ports) represent the output current source; the arrow indicates the positive direction of the output current.

Variables

Use the parameter group Initial Targets to set the priority and initial target values for the block parameter variables before modeling. For more information, see Configuring physical blocks using target values.

Ports

Conserving

# + — control port
electricity

Details

The positive terminal of the control circuit.

Program usage name

p1

# — control port
electricity

Details

The negative terminal of the control circuit.

Program usage name

n1

# i — output current source
electricity

Details

The terminal of the output current source.

Program usage name

head

# i — output current source
electricity

Details

The terminal of the output current source.

Program usage name

tail

Parameters

Parameters

# Current gain — current gain factor

Details

The ratio of the output current to the current flowing through the control circuit; a dimensionless coefficient.

Default value

1

Program usage name

gain

Evaluatable

Yes