AR-EL-55 RX

Getting the words of the PC ARINC 429.

blockType: CFunction

Path in the library:

/RITM/RITMex ARINC 429/RITMeX AR-EL-55/AR-EL-55 RX

Description

To work with the block, install/update the support package RITM blocks.

Block AR-EL-55 RX it is used to get the words of the PC ARINC 429.

Ports

Output

# Size — the number of received PC words recorded in the array Data
vector

Details
Data types

uint32

Complex numbers support

No

# Data — array of accepted PC words
vector

Details
Data types

uint32

Complex numbers support

No

Parameters

Parameters

# Номер модуля: — unique module identification when more than one I/O module of the same type is installed in a real-time machine.
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8

Details

It is used to uniquely identify a module when more than one I/O module of the same type is installed in a real-time machine. The module numbers are signed on the KPM "RHYTHM" building.

Values

1 | 2 | 3 | 4 | 5 | 6 | 7 | 8

Default value

1

Program usage name

m_boardNum

Tunable

No

Evaluatable

Yes

# Номер канала: — the number of the receiving channel to which the serial code will be received
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16

Details
Values

1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16

Default value

1

Program usage name

m_chNum

Tunable

No

Evaluatable

Yes

# Максимальное число слов ПК: — the largest number of consecutive code words available for reception in 1 calculation step

Details

The largest number of consecutive code words available for reception in 1 calculation step. No more than 255 words is the size of the inner ring buffer. If it overflows, the unread words will be replaced with newer ones.

Default value

0.0

Program usage name

m_maxWordNum

Tunable

No

Evaluatable

Yes

# Шаг расчета: — calculation step in seconds for receiving PC words

Details
Default value

-1

Program usage name

m_smplT

Tunable

No

Evaluatable

Yes