Engee documentation

LCARD L502 SAW

Generation of a high-frequency sawtooth signal at the analog outputs of the L-Card L-502 I/O module.

blockType: EngeeFunction

Path in the library:

/Interfaces/LCARD/LCARD L502 SAW

Description

To work with the block, install/update the support package. equipment.

Block LCARD L502 SAW It is used to generate a high-frequency sawtooth signal at the analog outputs of the L-Card L-502 I/O module.

Ports

Input

# The amplitude, In — signal amplitude
scalar

Details
Data types

Float64

Complex numbers support

No

# Frequency, Hz — signal frequency
scalar

Details
Data types

Float64

Complex numbers support

No

# Phase, with — the initial phase of the signal
scalar

Details
Data types

Float64

Complex numbers support

No

Parameters

Параметры

# Номер модуля: — the string serial identifier of the L-Card L-502 module

Details

You can get it on the front of the board or using the Engee hardware support package. For more information, see L-CARD L-502.

Default value

"default"

Program usage name

m_module_id

Tunable

No

Evaluatable

Yes

# Номер канала: — number of DAC channels for input
1 | 2

Details
Values

1 | 2

Default value

1

Program usage name

m_channel_num

Tunable

No

Evaluatable

Yes

# Амплитуда, В: — initial amplitude during signal initialization

Details
Default value

2.0

Program usage name

m_amplitude

Tunable

No

Evaluatable

Yes

# Частота, Гц: — the initial frequency of the signal

Details
Default value

20000.0

Program usage name

m_freq

Tunable

No

Evaluatable

Yes

# Фаза, с: — initial phase of the signal

Details
Default value

0

Program usage name

m_phase

Tunable

No

Evaluatable

Yes

# Шаг расчёта, с: — calculation step in seconds for generating a sawtooth signal

Details
Default value

-1

Program usage name

m_sample_time

Tunable

No

Evaluatable

Yes