Engee documentation

RITM Plot

Visualization of signals on the KPM "RHYTHM" monitor.

blockType: CFunction

Path in the library:

/RITM/RITM Plot/RITM Plot

Description

Block RITM Plot It is used to visualize the signals on the KPM "RHYTHM" monitor. Each block has its own graph on the KPM "RHYTHM" monitor, which can contain up to 3 signals.

Blocks RITM Plot and RITM Spectrum they don’t work within the same model - use only one of the blocks.

Ports

Input

# IN_1 — the curve on the graph of the KPM "RHYTHM" monitor
scalar

Details

The number of inputs depends on the value of the parameter Number of signals.

Data types

double

Complex numbers support

No

Parameters

Parameters

# mBlockAmountLabel — the number of chart windows on the KPM "RHYTHM" monitor
1 | 2 | 3 | 4 | 5

Details
Values

1 | 2 | 3 | 4 | 5

Default value

1

Program usage name

m_block_amount

Tunable

No

Evaluatable

Yes

# mNumPlotLabel — the number of the chart window on the KPM "RHYTHM" monitor or the number of the RITM Plot block.
1 | 2 | 3 | 4 | 5

Details
Values

1 | 2 | 3 | 4 | 5

Default value

1

Program usage name

m_num_plot

Tunable

No

Evaluatable

Yes

# mGraphSignatureLabel — the signature of the chart window on the KPM "RHYTHM" monitor

Details
Default value

"Plot"

Program usage name

m_Graph_signature

Tunable

No

Evaluatable

Yes

# mPortAmountLabel — the number of ports is equal to the number of curves of the graph window on the KPM "RHYTHM" monitor
1 | 2 | 3

Details
Values

1 | 2 | 3

Default value

1

Program usage name

m_port_amount

Tunable

No

Evaluatable

Yes

# mPointsAmountLabel — the number of points on the graph to display

Details
Default value

1000

Program usage name

m_points_amount

Tunable

No

Evaluatable

Yes

Usage Notes

The discretization of the graph is equal to the block calculation step. The parameter Number of points to display sets the window length: only the last N points are visible on the graph; as new ones are added, the old ones are deleted.

To prepare the data before RITM Plot It is recommended to use Rate Transition and Data Type Conversion Inherited.