Engee documentation

BA-IS-XX PWM

Page in progress.

Generation of PWM signals with usage of the RITMeX BA-IS-XX I/O module.

ba is xx pwm ru

Description

The unit is used to generate PWM signals with usage of the RITMeX BA-IS-XX I/O module.

Ports

Input

Period - PWM period value in seconds
scalar

Square - PWM duty cycle value in per cent (from 0 to 100 %)
scalar

Parameters

Module number - unique module identification
1 (by default) | 2 | 3 | 4 | 5 | 6 | 7 | 8

Details

Used to uniquely identify a module when more than one I/O module of the same type is installed in a real-time machine.

Module numbers are signed on the housing of the RITM.

Channel number - PWM channel number
1 (By default) | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32

Calculation step - calculation step in seconds with which the PWM period and rate values are changed from the real-time application
`-1 (By default).