Engee documentation

Detect Decrease

Signal slice detection.

detect decrease

Description

The Detect Decrease block determines that the current value of the input signal is strictly less than the previous value.

  • The output signal takes the value true (1) if the current value of the input signal is less than its previous value.

  • The output signal takes the value false (0) if the current value of the input signal is greater than or equal to its previous value.

This block can be used only with discrete solvers.

Ports

Input

Port_1 - input signal
scalar | vector | matrix

Input signal as a scalar, vector or matrix.

Data types: Float16, Float32, Float64, Int8, Int16, Int32, Int64, UInt8, UInt16, UInt32, UInt64, Bool.

Output

Port_1 - output signal
0 | 1
  • The output signal takes the value true (1) if the current value of the input signal is less than its previous value.

  • The output signal takes the value false (0) if the current value of the input signal is greater than or equal to its previous value.

Data types: Bool, UInt8.

Parameters

Initial condition - initial value of input signal
0 (by default) | scalar | vector

Sets the initial condition of the input signal U/z.

Usage in program code

Block parameter

vinit

Values

scalar | vector

* By default*

0

Output data type - output data type
Bool (by default) | UInt8

Set the output data type to Bool or UInt8.

Usage in program code

Block parameter

OutDataTypeStr

Values

Bool | UInt8

By default

Bool

Additional options

C code generation: Yes