BA-IS-XX RF9-SETUP-LOGIC

Setting the logical channels of the RX/TX SDR platform RF9 of the BA-IS-XX module on the RITM

blockType: CFunction

Path in the library:

/RITM/RITMeX BA-IS-XX/BA-IS-XX RF9/BA-IS-XX RF9-SETUP-LOGIC

Description

To work with the block, install/update the support package RITM blocks.

Block BA-IS-XX RF9-SETUP-LOGIC It is used to configure the RX/TX SDR logical channels of the RF9 platform of the BA-IS-XX module on the RITM

Parameters

Parameters

# Номер модуля: — serial number of the module
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8

Details

Serial number of the BA-IS-XX module on the RITM chassis (only BA-IS-XX modules are counted in the numbering).

Values

1 | 2 | 3 | 4 | 5 | 6 | 7 | 8

Default value

1

Program usage name

m_module_idx

Tunable

No

Evaluatable

Yes

# Максимальное количество сэмплов DMA премника: — maximum number of samples

Details

The maximum number of samples allocated to the receiver’s DMA buffer and available for usage by processing units during execution.

Default value

4096

Program usage name

m_rx_samples

Tunable

No

Evaluatable

Yes

# Использовать DUT/DMA для передатчика — usage of DUT/DMA

Details

If the checkbox is unchecked, DUT/DMA for the transmitter is not used, the platform operates in the internal DDS generator mode; if the checkbox is unchecked, DUT/DMA for the transmitter is used, the specific mode is determined by the parameter Максимальное количество сэмплов DMA передатчика (0 для использования DUT):.

Default value

true (switched on)

Program usage name

m_dut_dma

Tunable

No

Evaluatable

Yes

# Максимальное количество сэмплов DMA передатчика (0 для использования DUT): — maximum number of samples

Details

This parameter determines the size of the memory that is allocated for reproducing the specified waveforms during execution in DMA mode with the usage of blocks BA-IS-XX RF9-PRODUCE-LFM, BA-IS-XX RF9-PRODUCE-HARMONIC, BA-IS-XX RF9-PRODUCE-ARBITRARY; to usage the DUT mode (Custom HDL model) here it is necessary to set the value 0.

Default value

2048

Program usage name

m_dma_samples

Tunable

No

Evaluatable

Yes

# Шаг расчёта, с: — block calculation step

Details

Block calculation step in seconds. Set the value −1 to inherit the model calculation step.

Default value

-1

Program usage name

m_sample_time

Tunable

No

Evaluatable

Yes