GP-LC-4x ADC
Receiving samples from the ADC channels of the RITMeX GP-LC-45 I/O module.
blockType: CFunction
|
Path in the library:
|
Description
| To work with the block, install/update the support package RITM blocks. |
Block GP-LC-4x ADC It is used to receive samples from the ADC channels of the RITMeX GP-LC-45 I/O module.
Specifications:
-
The number of channels is
32in common ground mode and16in differential mode. The bit depth is16bits. -
Measuring ranges are
±10V,±5V,±2V,±1V,±0.5V,±0.2V. -
The conversion frequency is
2MHz.
Ports
Output
#
adc
—
generation of the array of samples from ADC channels
vector
Details
The array size corresponds to the parameter Number of channels in the block.
| Data types |
|
| Complex numbers support |
No |
Parameters
Параметры
#
Номер модуля: —
unique module identification
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8
Details
Used when more than one I/O module of the same type is installed in a real-time machine.
| Values |
|
| Default value |
|
| Program usage name |
|
| Tunable |
No |
| Evaluatable |
Yes |
#
Диапазон: —
selecting the measuring range of the DAC
+-10В | +-5В | +-2В | +-1В | +-0.5В | +-0.2В
Details
| Values |
|
| Default value |
|
| Program usage name |
|
| Tunable |
No |
| Evaluatable |
Yes |
Details
Description missing.
| Default value |
|
| Program usage name |
|
| Tunable |
No |
| Evaluatable |
Yes |
#
Режим: —
ADC mode selection
32 канала: режим с общей землей | 16 каналов: дифференциальный режим
Details
| Values |
|
| Default value |
|
| Program usage name |
|
| Tunable |
No |
| Evaluatable |
Yes |
Details
Description missing.
| Default value |
|
| Program usage name |
|
| Tunable |
No |
| Evaluatable |
Yes |
#
Количество каналов: —
selection of the number of ADC channels to be used
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32
Details
| Values |
|
| Default value |
|
| Program usage name |
|
| Tunable |
No |
| Evaluatable |
Yes |
# Шаг расчёта, с: — Calculation step in seconds to obtain ADC readings in the real-time application
Details
| Default value |
|
| Program usage name |
|
| Tunable |
No |
| Evaluatable |
Yes |