GP-LC-4x DO
Sending values to the digital outputs of the RITMeX GP-LC-45 I/O module.
blockType: CFunction
|
Path in the library:
|
Description
| To work with the block, install/update the support package RITM blocks. |
Block GP-LC-4x DO It is used to send values to the digital outputs of the RITMeX GP-LC-45 I/O module.
Specifications:
-
The number of channels is `16'.
-
The voltage range is
0…+0.4In ("zero"),+2.4…+3.3In ("unit"). -
The output frequency is
1MHz.
Ports
Input
#
do
—
receiving a sampling array for transmission to digital outputs
`vector'
Details
The array size corresponds to the parameter Number of channels in the block.
| Data types |
|
| Complex numbers support |
No |
Parameters
Параметры
#
Номер модуля: —
unique module identification
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8
Details
Used when more than one I/O module of the same type is installed in a real-time machine.
| Values |
|
| Default value |
|
| Program usage name |
|
| Tunable |
No |
| Evaluatable |
Yes |
#
Количество каналов: —
selecting the number of digital output channels to be used
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16
Details
| Values |
|
| Default value |
|
| Program usage name |
|
| Tunable |
No |
| Evaluatable |
Yes |
# Шаг расчёта, с: — calculation step in seconds for sending counts to digital output channels from the real-time application
Details
| Default value |
|
| Program usage name |
|
| Tunable |
No |
| Evaluatable |
Yes |