Engee documentation

Bergeron Line (Three-Phase)

A three-phase Bergeron line modeled in Clark coordinates and parameterized by the values of the forward and zero sequences.

blockType: SubSystem

Path in the library:

/Physical Modeling/Electrical/Passive/Lines/Bergeron Line (Three-Phase)

Description

Block Bergeron Line (Three-Phase) simulates a three-phase power transmission line using the traveling wave method, taking into account the finite propagation time of an electromagnetic wave between the ends of the line. The line is modeled in Clark coordinates and is set by the length and linear parameters of the forward and zero sequences.

In contrast to the focused RLC model, Bergeron Line (Three-Phase) It takes into account the propagation delay between the ends of the line, which makes it possible to reproduce the dynamics of extended lines and the associated electromagnetic transients.

A specialized block is used to divide the power system model into parallel computing segments. Connector Bergeron Line (Three-Phase).

Ports

Conserving

# ~1 — three-phase port
electricity

Details

Three-phase electrical port for connecting the first end of the line to the electrical network.

Program usage name

port1

# ~2 — three-phase port
electricity

Details

Three-phase electrical port for connecting the second end of the line to the electrical network.

Program usage name

port2

Parameters

Main group

# Length, km — length of the power transmission line

Details

The length of the power transmission line.

Default value

100.0

Program usage name

line_length

Evaluatable

Yes

# Positive-sequence resistance, Ohm/km — active linear resistance of the forward sequence

Details

Active linear resistance of the forward sequence.

Default value

0.01

Program usage name

R1

Evaluatable

Yes

# Zero-sequence resistance, Ohm/km — active linear resistance of the zero sequence

Details

Active linear resistance of the zero sequence.

Default value

0.4

Program usage name

R0

Evaluatable

Yes

# Positive-sequence inductance, H/km — specific inductance of the direct sequence

Details

The specific inductance of the direct sequence.

Default value

0.001

Program usage name

L1

Evaluatable

Yes

# Zero-sequence inductance, H/km — specific inductance of the zero sequence

Details

The specific inductance of the zero sequence.

Default value

0.004

Program usage name

L0

Evaluatable

Yes

# Positive-sequence capacitance, F/km — specific capacity of the direct sequence

Details

The specific capacity of the direct sequence. This value must be greater than zero.

Default value

1e-8

Program usage name

C1

Evaluatable

Yes

# Zero-sequence capacitance, F/km — specific capacity of the zero sequence

Details

The specific capacity of the zero sequence. This value must be greater than zero.

Default value

8e-9

Program usage name

C0

Evaluatable

Yes

Sample time

# Sample time, s — sampling period

Details

Specify the sampling period of the block in seconds.

Default value

50e-6

Program usage name

sample_time

Evaluatable

Yes