Wye-Connected Variable Load
A three-phase variable load connected according to the Star scheme.
blockType: AcausalElectricPowerSystems.Passive.RLC_Assemblies.WyeConnectedVariableLoad
Path in the library:
|
Description
Block Wye-Connected Variable Load simulates a variable three-phase load connected according to the Star scheme. Each phase of the load contains a resistor. The unit calculates the resistance required to obtain an active power equal to the signal at the input port P at a given rated voltage. Thus, the block can represent an active load.
To ensure that the resistance is always greater than zero, the minimum active power consumed by the load is set. The minimum active power must be greater than zero.
Parameters
Main
Rated voltage — rated line voltage
24e3 V (by default)
The RMS value of the nominal line voltage for the resistance equation.
Minimum real power — minimum active power
1E3W (by default)
The minimum active power that a three-phase load dissipates when the rated voltage is applied. The value must be greater than 0.