Voltage Transformer

Page in progress.

Voltage Transformer (VT).

blockType: AcausalElectricPowerSystems.Passive.Transformers.Voltage

Path in the library:

/Physical Modeling/Electrical/Passive/Transformers/Voltage Transformer

Description

The Voltage Transformer block is a multiwinding transformer that can be modelled as a voltage transformer with different levels of nonlinearity.

The parameters group Initial Conditions is used to set the initial current or flux for each of the inductors, as well as for the load inductors in case the checkbox Include burden. is checked. Note that these values are not used if the Start simulation from steady state checkbox is selected in the solver configuration Solver Configuration.

The group of parameters Parasitic represents small parasitic effects. Small parallel conductances may be required for modelling some circuit topologies.

For more information on the equations and modes implemented in the block see Nonlinear Transformer.

Ports

Conserving

# 1+ — positive terminal of the first winding
electricity

Details

Electrical port, represents the terminal of the first winding with positive polarity.

Program usage name

p1

# 1- — negative terminal of the first winding
electricity

Details

Electrical port, represents the terminal of the first winding with negative polarity.

Program usage name

n1

# 2+ — positive terminal of the second winding
electricity

Details

Electricity port, represents the terminal of the second winding with positive polarity.

Dependencies

To use this port, uncheck Include burden.

Program usage name

p2

# 2- — negative terminal of the second winding
electricity

Details

Electricity port, represents the terminal of the second winding with negative polarity.

Dependencies

To use this port, uncheck Include burden.

Program usage name

n2

# 3+ — positive terminal of the third winding
electricity

Details

Electricity port, represents the terminal of the third winding with positive polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings value. Three, Four, Five or Six.

Program usage name

p3

# 3- — negative terminal of the third winding
electricity

Details

Electricity port, represents the terminal of the third winding with negative polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings value. Three, Four, Five or Six.

Program usage name

n3

# 4+ — positive terminal of the fourth winding
electricity

Details

Electricity port, represents the terminal of the fourth winding with positive polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings value. Four, Five or Six.

Program usage name

p4

# 4- — negative terminal of the fourth winding
electricity

Details

Electricity port, represents the terminal of the fourth winding with negative polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings value. Four, Five or Six.

Program usage name

n4

# 5+ — positive terminal of the fifth winding
electricity

Details

Electricity port, represents the terminal of the fifth winding with positive polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings the value of Five or Six.

Program usage name

p5

# 5- — negative terminal of the fifth winding
electricity

Details

Electricity port, represents the terminal of the fifth winding with negative polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings the value of Five or Six.

Program usage name

n5

# 6+ — positive terminal of the sixth winding
electricity

Details

Electricity port, represents the terminal of the sixth winding with positive polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings the value of Six.

Program usage name

p6

# 6- — negative terminal of the sixth winding
electricity

Details

Electricity port, represents the terminal of the sixth winding with negative polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings the value of Six.

Program usage name

n6

Output

# v2 — second winding voltage
scalar

Details

Voltage of the second winding.

Dependencies

To use this port, select the checkbox Include burden.

Data types

Float64.

Complex numbers support

No

# v3 — voltage of the third winding.
scalar

Details

Voltage of the third winding.

Dependencies

To use this port, select the checkbox Include burden, and set the value for the parameters Number of windings. Three, Four, Five or Six.

Data types

Float64.

Complex numbers support

No

# v4 — fourth winding voltage
scalar

Details

Voltage of the fourth winding.

Dependencies

To use this port, select the checkbox Include burden, and set the value for the parameters Number of windings to . Four, Five or Six.

Data types

Float64.

Complex numbers support

No

# v5 — fifth winding voltage
scalar

Details

Voltage of the fifth winding.

Dependencies

To use this port, select the checkbox Include burden, and set the parameters Number of windings to the value of Five or Six.

Data types

Float64.

Complex numbers support

No

# v6 — sixth winding voltage
scalar

Details

Voltage of the sixth winding.

Dependencies

To use this port, select the checkbox Include burden, and set the parameters Number of windings to a value of Six.

Data types

Float64.

Complex numbers support

No

Parameters

Main

# Number of windings — switching between two-, three-, four-, five- and six-winding transformers
Two | Three | Four | Five | Six

Details

Switching between two-, three-, four-, five- and six-winding transformers.

  • Two - the unit simulates a two-winding transformer.

  • Three - The block simulates a three-winding transformer.

  • Four - The block simulates a four-winding transformer.

  • Five - The block simulates a five-winding transformer.

  • Six - The block simulates a six-winding transformer.

Values

Two | Three | Four | Five | Six

Default value

Two

Program usage name

N_windings

Evaluatable

No

# Turns ratio parameterization by — option for setting the transformer ratio of the VT
Number of turns

Details

Select one of the following methods for setting the VT ratio:

  • Number of turns - through the number of turns.

Values

Number of turns

Default value

Number of turns

Program usage name

turns_ratio_parameterization

Evaluatable

No

# First winding number of turns — number of turns of the first winding

Details

Number of turns of the first winding wire of the transformer.

Dependencies

To use this parameter, set the parameters Turns ratio parameterization by to . Number of turns.

Default value

220

Program usage name

N_1

Evaluatable

Yes

# Second winding number of turns — number of turns of the second winding

Details

Number of turns of the second winding wire of the transformer.

Dependencies

To use this parameter, set the parameters Turns ratio parameterization by to . Number of turns.

Default value

100

Program usage name

N_2

Evaluatable

Yes

# Third winding number of turns — number of turns of the third winding

Details

Number of turns of the third winding wire of the transformer.

Dependencies

To use this parameter, set the Turns ratio parameterization by parameters to and the parameters to . Number of turns`and set the parameters Number of windings. `Three, Four, Five or Six.

Default value

100

Program usage name

N_3

Evaluatable

Yes

# Fourth winding number of turns — number of turns of the fourth winding

Details

Number of turns of the fourth winding wire of the transformer.

Dependencies

To use this parameter, set the parameters Turns ratio parameterization by to the value of Number of turns`and set the Number of windings parameters to `Four, Five or Six.

Default value

100

Program usage name

N_4

Evaluatable

Yes

# Fifth winding number of turns — number of turns of the fifth winding

Details

Number of turns of the fifth winding wire of the transformer.

Dependencies

To use this parameter, set the parameters Turns ratio parameterization by to the value of Number of turns`and set the Number of windings parameters to `Five or Six.

Default value

100

Program usage name

N_5

Evaluatable

Yes

# Sixth winding number of turns — number of turns of the sixth winding

Details

Number of turns of the sixth winding wire of the transformer.

Dependencies

To use this parameter, set the parameters Turns ratio parameterization by to the value of Number of turns`and set the Number of windings parameters to `Six.

Default value

100

Program usage name

N_6

Evaluatable

Yes

# Winding parameterized by — type of winding distribution representation
Combined primary and secondary values | Separate primary and secondary values

Details

The method of dissipation in the winding. Defined as:

  • Combined primary and secondary values - use concentrated resistance and inductance values representing the combined leakage in the primary and secondary windings.

  • Separate primary and secondary values - use separate resistances and inductances to represent the leakage in the primary and secondary windings.

Dependencies

To use this parameter, set the parameter Number of windings to Two.

Values

Combined primary and secondary values | Separate primary and secondary values

Default value

Combined primary and secondary values

Program usage name

winding_parameterization

Evaluatable

No

# Combined winding resistance — total active resistance of windings
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The concentrated equivalent active resistance Req, which represents the combined power losses of the first and second windings.

Dependencies

To use this parameter, set the parameters Winding parameterized by to . Combined primary and secondary values.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

0.01 Ohm

Program usage name

R_eq

Evaluatable

Yes

# Combined leakage inductance — total scattering inductance
H | mH | nH | uH

Details

The cumulative equivalent inductance Leq, which is the combined magnetic flux losses of the first and second windings.

Dependencies

To use this parameter, set the parameters Winding parameterized by to . Combined primary and secondary values.

Units

H | mH | nH | uH

Default value

0.0001 H

Program usage name

L_eq

Evaluatable

Yes

# First winding resistance — active resistance of the first winding
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The active resistance R1, which represents the power loss of the first winding.

Dependencies

To use this parameter, set the Winding parameterized by parameters to the value of Separate primary and secondary values or set the Number of windings parameters to . Three, Four, Five or Six.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

5.0 Ohm

Program usage name

R_1

Evaluatable

Yes

# First leakage inductance — dissipation inductance of the first winding
H | mH | nH | uH

Details

The inductance L1, which represents the magnetic flux losses of the first winding.

Dependencies

To use this parameter, set the Winding parameterized by parameters to the value of Separate primary and secondary values or set the Number of windings parameters to . Three, Four, Five or Six.

Units

H | mH | nH | uH

Default value

0.0001 H

Program usage name

L_1

Evaluatable

Yes

# Second winding resistance — active resistance of the second winding
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The active resistance R2, which represents the power loss of the second winding.

Dependencies

To use this parameter, set the Winding parameterized by parameters to the value of Separate primary and secondary values or set the Number of windings parameters to . Three, Four, Five or Six.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

5.0 Ohm

Program usage name

R_2

Evaluatable

Yes

# Second leakage inductance — dissipation inductance of the second winding
H | mH | nH | uH

Details

The inductance L2, which represents the magnetic flux losses of the second winding.

Dependencies

To use this parameter, set the Winding parameterized by parameters to the value of Separate primary and secondary values or set the Number of windings parameters to . Three, Four, Five or Six.

Units

H | mH | nH | uH

Default value

0.0001 H

Program usage name

L_2

Evaluatable

Yes

# Third winding resistance — active resistance of the third winding
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The active resistance R3, which represents the power loss of the third winding.

Dependencies

To use this parameter, set the parameter Number of windings to . Three, Four, Five or Six.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

5.0 Ohm

Program usage name

R_3

Evaluatable

Yes

# Third leakage inductance — dissipation inductance of the third winding
H | mH | nH | uH

Details

The L3 inductance, which represents the magnetic flux losses of the third winding.

Dependencies

To use this parameter, set the parameter Number of windings to the value of Three, Four, Five or Six.

Units

H | mH | nH | uH

Default value

0.0001 H

Program usage name

L_3

Evaluatable

Yes

# Fourth winding resistance — active resistance of the fourth winding
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The active resistance R4, which represents the power loss of the fourth winding.

Dependencies

To use this parameter, set the parameter Number of windings to . Four, Five or Six.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

5.0 Ohm

Program usage name

R_4

Evaluatable

Yes

# Fourth leakage inductance — dissipation inductance of the fourth winding
H | mH | nH | uH

Details

The L4 inductance, which represents the magnetic flux losses of the fourth winding.

Dependencies

To use this parameter, set the parameter Number of windings to . Four, Five or Six.

Units

H | mH | nH | uH

Default value

0.0001 H

Program usage name

L_4

Evaluatable

Yes

# Fifth winding resistance — active resistance of the fifth winding
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The active resistance R5, which represents the power loss of the fifth winding.

Dependencies

To use this parameter, set the parameters Number of windings to the value of Five or Six.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

5.0 Ohm

Program usage name

R_5

Evaluatable

Yes

# Fifth leakage inductance — dissipation inductance of the fifth winding
H | mH | nH | uH

Details

The L5 inductance, which represents the magnetic flux losses of the fifth winding.

Dependencies

To use this parameter, set the parameters Number of windings to the value of Five or Six.

Units

H | mH | nH | uH

Default value

0.0001 H

Program usage name

L_5

Evaluatable

Yes

# Sixth winding resistance — active resistance of the sixth winding
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The active resistance R6, which represents the power loss of the sixth winding.

Dependencies

To use this parameter, set the parameter Number of windings to the value of Six.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

5.0 Ohm

Program usage name

R_6

Evaluatable

Yes

# Sixth leakage inductance — dissipation inductance of the sixth winding
H | mH | nH | uH

Details

The L6 inductance, which represents the magnetic flux losses of the sixth winding.

Dependencies

To use this parameter, set the parameter Number of windings to the value of Six.

Units

H | mH | nH | uH

Default value

0.0001 H

Program usage name

L_6

Evaluatable

Yes

Magnetization

# Magnetization resistance — active magnetising resistance
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The active resistance Rm representing the magnetic losses in the transformer core.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

100.0 Ohm

Program usage name

R_m

Evaluatable

Yes

# Magnetization inductance parameterized by — block parameterization
Single inductance (linear) | Single saturation point | Magnetic flux versus current characteristic | Magnetic flux density versus magnetic field strength characteristic | Magnetic flux density versus magnetic field strength characteristic with hysteresis | Voltage versus current characteristic

Details

A method for parameterising a block. Defined as:

  • Single inductance (linear) - values for the number of turns, unsaturated and saturated inductances, saturation magnetic flux and parasitic parallel conductivity are specified. This option is used by default.

  • Single saturation point - The values for the number of turns, unsaturated inductance and parasitic parallel conductivity are specified.

  • Magnetic flux versus current characteristic - In addition to the number of turns and the value of the parasitic parallel conductance, the current vector and the magnetic flux vector are given to complete the magnetic flux-current table.

  • Magnetic flux density versus magnetic field strength characteristic - In addition to the number of turns and the parasitic parallel conductance value, the effective length and cross-sectional area of the core are given, as well as the magnetic field strength vector and the magnetic induction vector to complete the magnetic induction versus magnetic field strength table.

  • Magnetic flux density versus magnetic field strength characteristic with hysteresis - In addition to the number of turns, effective length and cross-sectional area of the core, the values of the initial derivative of the angysteresis B-H curve, magnetic induction and field strength at a certain point of the B-H curve, as well as the reversible magnetisation coefficient, volume coupling coefficient and interdomain coupling coefficient to determine the magnetic induction as a function of the current value and history of the magnetic field strength are given.

  • Voltage versus current characteristic - setting saturation through the volt-ampere characteristic (VAC).

Values

Single inductance (linear) | Single saturation point | Magnetic flux versus current characteristic | Magnetic flux density versus magnetic field strength characteristic | Magnetic flux density versus magnetic field strength characteristic with hysteresis | Voltage versus current characteristic

Default value

Voltage versus current characteristic

Program usage name

saturation_parameterization

Evaluatable

No

# Magnetic field strength vector, H — vector of magnetic field strength values
A/m

Details

Magnetic field strength values used to fill in the table of dependence of magnetic induction on magnetic field strength.

Dependencies

To use this parameter, set the Magnetization inductance parameterized by parameters to . Magnetic flux versus current characteristic.

Units

A/m

Default value

[0.0, 200.0, 400.0, 600.0, 800.0, 1000.0] A/m

Program usage name

H_vector

Evaluatable

Yes

# Magnetic flux density vector, B — vector of magnetic induction values
G | T

Details

Magnetic induction values used to fill in the table of dependence of magnetic induction on magnetic field strength.

Dependencies

To use this parameter, set the Magnetization inductance parameterized by parameters to . Magnetic flux versus current characteristic.

Units

G | T

Default value

[0.0, 0.81, 1.25, 1.42, 1.48, 1.49] T

Program usage name

B_vector

Evaluatable

Yes

# Effective length — effective core length
m | cm | ft | in | km | mi | mm | um | yd

Details

The effective core length, i.e. the average length of the magnetic flux path.

Dependencies

To use this parameter, set the parameters Magnetization inductance parameterized by to Magnetic flux density versus magnetic field strength characteristic or Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

m | cm | ft | in | km | mi | mm | um | yd

Default value

0.2 m

Program usage name

effective_length

Evaluatable

Yes

# Effective cross-sectional area — effective cross-sectional area
m^2 | cm^2 | ft^2 | in^2 | km^2 | mi^2 | mm^2 | um^2 | yd^2

Details

The effective cross-sectional area of the core, i.e. the average area of the magnetic flux path.

Dependencies

To use this parameter, set the parameters Magnetization inductance parameterized by to the value of Magnetic flux density versus magnetic field strength characteristic or Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

m^2 | cm^2 | ft^2 | in^2 | km^2 | mi^2 | mm^2 | um^2 | yd^2

Default value

2e-4 m^2

Program usage name

A_effective

Evaluatable

Yes

# Unsaturated inductance — unsaturated inductance
H | mH | nH | uH

Details

The inductance value used when the transformer is operating in the linear region.

Dependencies

To use this parameter, set the parameters Magnetization inductance parameterized by to Single inductance (linear) or Single saturation point.

Units

H | mH | nH | uH

Default value

4e-2 H

Program usage name

L_m

Evaluatable

Yes

# Saturated inductance — saturable inductance
H | mH | nH | uH

Details

The inductance value used when the transformer is operating in the saturation zone.

Dependencies

To use this parameter, set the parameter Magnetization inductance parameterized by to the value of Single saturation point.

Units

H | mH | nH | uH

Default value

1e-2 H

Program usage name

L_m_sat

Evaluatable

Yes

# Current vector, i — current vector
A | MA | kA | mA | nA | pA | uA

Details

Current values used to populate the magnetic flux-current table.

Dependencies

To use this parameter, set the Magnetization inductance parameterized by parameters to Magnetic flux versus current characteristic.

Units

A | MA | kA | mA | nA | pA | uA

Default value

[0.0, 0.4, 0.8, 1.2, 1.6, 2.0] A

Program usage name

i_vector

Evaluatable

Yes

# Magnetic flux vector, Φ — vector of magnetic flux values
Wb | N*m/A | mN*m/A

Details

Magnetic flux values used to populate the magnetic flux-current table.

Dependencies

To use this parameter, set the parameters Magnetization inductance parameterized by to . Magnetic flux versus current characteristic.

Units

Wb | N*m/A | mN*m/A

Default value

[0.0, 0.161, 0.25, 0.284, 0.295, 0.299] * 1e-3 Wb

Program usage name

Phi_vector

Evaluatable

Yes

# Current vector for V-I option, (secondary side - RMS) — vector of effective values of current VAC
A | MA | kA | mA | nA | pA | uA

Details

The vector of effective values of the SAC current.

Dependencies

To use this parameter, set the parameter Magnetization inductance parameterized by to . Voltage versus current characteristic.

Units

A | MA | kA | mA | nA | pA | uA

Default value

[0.0, 0.1414, 0.2828, 0.4243, 0.5657, 0.7071] A

Program usage name

I_RMS_vector

Evaluatable

Yes

# Voltage vector for V-I option, (secondary side - RMS) — vector of effective values of voltage VAC
V | MV | kV | mV

Details

The vector of effective values of the VAC voltage.

Dependencies

To use this parameter, set the parameter Magnetization inductance parameterized by to . Voltage versus current characteristic.

Units

V | MV | kV | mV

Default value

[0.0, 7.1530, 11.1072, 12.6178, 13.1065, 13.2842] V

Program usage name

V_RMS_vector

Evaluatable

Yes

# System frequency — network frequency
Hz | GHz | MHz | kHz

Details

Network frequency.

Dependencies

To use this parameter, set the Magnetization inductance parameterized by parameters to Voltage versus current characteristic.

Units

Hz | GHz | MHz | kHz

Default value

50.0 Hz

Program usage name

f

Evaluatable

Yes

# Saturation magnetic flux — saturated magnetic flux
Wb | N*m/A | mN*m/A

Details

The value of the magnetic flux at which the transformer becomes saturated.

Dependencies

To use this parameter, set the parameters Magnetization inductance parameterized by to . Single saturation point.

Units

Wb | N*m/A | mN*m/A

Default value

0.00016 Wb

Program usage name

Phi_sat

Evaluatable

Yes

# Anhysteretic B-H gradient when H is zero — derivative of the B-H anhysteresis curve near zero field strength
H/m | mH/m | nH/m | uH/m | H/km | mH/km | T*m/A

Details

The derivative of the anhysteresis (no hysteresis) B-H curve near zero field strength. Set as the average of the derivative of the positive and negative hysteresis curves.

Dependencies

To use this parameter, set the parameter Magnetization inductance parameterized by to . Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

H/m | mH/m | nH/m | uH/m | H/km | mH/km | T*m/A

Default value

0.005 T*m/A

Program usage name

dB_dH_0

Evaluatable

Yes

# Flux density point on anhysteretic B-H curve — value of magnetic induction at the point on the angysteresis curve B-H
G | T

Details

Specify the value of magnetic induction at a point on the anhysteresis curve. The most accurate option is to select the point at high field strength when the positive and negative hysteresis curves coincide.

Dependencies

To use this parameter, set the parameter Magnetization inductance parameterized by to . Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

G | T

Default value

1.49 T

Program usage name

B_anhysteretic

Evaluatable

Yes

# Corresponding field strength — corresponding field strength
A/m

Details

Corresponding field strength for the point given by the parameters Flux density point on anhysteretic B-H curve.

Dependencies

To use this parameter, set the Magnetization inductance parameterized by parameters to . Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

A/m

Default value

1000.0 A/m

Program usage name

H_anhysteretic

Evaluatable

Yes

# Coefficient for reversible magnetization, c — reversible magnetisation coefficient

Details

The fraction of magnetisation that is reversible. The value must be greater than zero and less than one.

Dependencies

To use this parameter, set the parameter Magnetization inductance parameterized by to the value of Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Default value

0.1

Program usage name

c

Evaluatable

Yes

# Bulk coupling coefficient, K — volume coupling coefficient
A/m

Details

A parameter of the Giles-Atherton model that primarily determines the value of field strength at which the B-H curve crosses the line of zero magnetic induction.

Dependencies

To use this parameter, set the parameters Magnetization inductance parameterized by to . Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

A/m

Default value

200.0 A/m

Program usage name

K

Evaluatable

Yes

# Inter-domain coupling factor, α — interdomain coefficient

Details

A Giles-Atherton parameter affecting primarily the points of intersection of the B-H curves with the zero field strength line. Typical values range from 1e-4 to 1e-3.

Dependencies

To use this parameter, set the parameter Magnetization inductance parameterized by to the value of Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Default value

1e-4

Program usage name

alpha

Evaluatable

Yes

# Interpolation option — interpolation option
Linear | Smooth

Details

The interpolation option of the lookup table. Defined as:

  • Linear - select this option to get the best performance.

  • Smooth - select this option to obtain a continuous curve with continuous first order derivatives.

Values

Linear | Smooth

Default value

Linear

Program usage name

interpolation_option

Evaluatable

No

Burden

# Include burden — load of secondary windings of VTs

Details

If this checkbox is selected, an internal load is connected to the secondary windings, the output ports will change from electrical to directional (scalars).

Default value

false (switched off)

Program usage name

include_burden

Evaluatable

No

# Burden type — load type
R | L | Series RL

Details

Load Type:

  • R - Active.

  • L - inductive.

  • Series RL - series active-inductive.

Dependencies

To use this parameter, select the check box Include burden.

Values

R | L | Series RL

Default value

R

Program usage name

burden_type

Evaluatable

No

# Second winding burden resistance — active load resistance of the second winding
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The active load resistance of the second winding.

Dependencies

To use this parameter, tick the checkbox Include burden, and for the parameter Burden type set the value to R or Series RL;

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

5.0 Ohm

Program usage name

R_burden2

Evaluatable

Yes

# Second winding burden inductance — load inductance of the second winding
H | mH | nH | uH

Details

Load inductance of the second winding.

Dependencies

To use this parameter, tick the checkbox Include burden, and for the parameter Burden type set the value to L or Series RL;

Units

H | mH | nH | uH

Default value

0.001 H

Program usage name

L_burden2

Evaluatable

Yes

# Third winding burden resistance — active load resistance of the third winding
Ohm | GOhm | MOhm | kOhm | mOhm

Details

Active load resistance of the third winding.

Dependencies

To use this parameters:

  • select the check box Include burden;

  • set the Burden type parameters to R or Series RL;

  • set the Number of windings parameters to Three, Four, Five or Six.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

5.0 Ohm

Program usage name

R_burden3

Evaluatable

Yes

# Third winding burden inductance — load inductance of the third winding
H | mH | nH | uH

Details

Load inductance of the third winding.

Dependencies

To use this parameters:

  • select the check box Include burden;

  • set the Burden type parameters to L or Series RL;

  • set the Number of windings parameters to Three, Four, Five or Six.

Units

H | mH | nH | uH

Default value

0.001 H

Program usage name

L_burden3

Evaluatable

Yes

# Fourth winding burden resistance — active load resistance of the fourth winding
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The active load resistance of the fourth winding.

Dependencies

To use this parameters:

  • Select the checkbox Include burden;

  • set the Burden type parameters to R or Series RL;

  • set the Number of windings parameters to Four, Five or Six.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

5.0 Ohm

Program usage name

R_burden4

Evaluatable

Yes

# Fourth winding burden inductance — load inductance of the fourth winding
H | mH | nH | uH

Details

Load inductance of the fourth winding.

Dependencies

To use this parameters:

  • select the check box Include burden;

  • set the Burden type parameters to L or Series RL;

  • set the Number of windings parameters to Four, Five or Six.

Units

H | mH | nH | uH

Default value

0.001 H

Program usage name

L_burden4

Evaluatable

Yes

# Fifth winding burden resistance — active load resistance of the fifth winding
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The active load resistance of the fifth winding.

Dependencies

To use this parameters:

  • select the check box Include burden;

  • set the Burden type parameters to R or Series RL;

  • set the Number of windings parameters to Five or Six.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

5.0 Ohm

Program usage name

R_burden5

Evaluatable

Yes

# Fifth winding burden inductance — load inductance of the fifth winding
H | mH | nH | uH

Details

The load inductance of the fifth winding.

Dependencies

To use this parameters:

  • select the check box Include burden;

  • set the Burden type parameters to L or Series RL;

  • set the Number of windings parameters to Five or Six.

Units

H | mH | nH | uH

Default value

0.001 H

Program usage name

L_burden5

Evaluatable

Yes

# Sixth winding burden resistance — active load resistance of the sixth winding
Ohm | GOhm | MOhm | kOhm | mOhm

Details

The active load resistance of the sixth winding.

Dependencies

To use this parameters:

  • select the check box Include burden;

  • set the Burden type parameters to R or Series RL;

  • set the Number of windings parameters to Six.

Units

Ohm | GOhm | MOhm | kOhm | mOhm

Default value

5.0 Ohm

Program usage name

R_burden6

Evaluatable

Yes

# Sixth winding burden inductance — load inductance of the sixth winding
H | mH | nH | uH

Details

Load inductance of the sixth winding.

Dependencies

To use this parameters:

  • select the check box Include burden;

  • set the Burden type parameters to L or Series RL;

  • set the Number of windings parameters to Six.

Units

H | mH | nH | uH

Default value

0.001 H

Program usage name

L_burden6

Evaluatable

Yes

Initial Conditions

# Combined leakage current — initial current of the total dissipation inductance
A | MA | kA | mA | nA | pA | uA

Details

Initial value of the total dissipation inductance current.

Dependencies

To use this parameter, set the parameter Winding parameterized by to . Combined primary and secondary values.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_Leq_start

Evaluatable

Yes

# First leakage inductance current — initial current of the first winding dissipation inductance
A | MA | kA | mA | nA | pA | uA

Details

Initial value of the dissipation inductance current of the first winding of the transformer.

Dependencies

To use this parameter, set the parameters Winding parameterized by to Separate primary and secondary values or set the parameters Number of windings. Three, Four, Five or Six.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_L1_start

Evaluatable

Yes

# Second leakage inductance current — initial current of the second winding dissipation inductance
A | MA | kA | mA | nA | pA | uA

Details

Initial value of the dissipation inductance current of the second winding of the transformer.

Dependencies

To use this parameter, set the parameters Winding parameterized by to Separate primary and secondary values or set the parameters Number of windings. Three, Four, Five or Six.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_L2_start

Evaluatable

Yes

# Third leakage inductance current — initial current of the third winding dissipation inductance
A | MA | kA | mA | nA | pA | uA

Details

Initial value of the dissipation inductance current of the third winding of the transformer.

Dependencies

To use this parameter, set the parameters Number of windings to . Three, Four, Five or Six.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_L3_start

Evaluatable

Yes

# Fourth leakage inductance current — initial current of the fourth winding dissipation inductance
A | MA | kA | mA | nA | pA | uA

Details

Initial value of the dissipation inductance current of the fourth winding of the transformer.

Dependencies

To use this parameter, set the parameters Number of windings to . Four, Five or Six.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_L4_start

Evaluatable

Yes

# Fifth leakage inductance current — initial current of the fifth winding dissipation inductance
A | MA | kA | mA | nA | pA | uA

Details

Initial value of the dissipation inductance current of the fifth winding of the transformer.

Dependencies

To use this parameter, set the parameters Number of windings to Five or Six.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_L5_start

Evaluatable

Yes

# Sixth leakage inductance current — initial current of the sixth winding dissipation inductance
A | MA | kA | mA | nA | pA | uA

Details

Initial value of the dissipation inductance current of the sixth winding of the transformer.

Dependencies

To use this parameter, set the parameters Number of windings. Six.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_L6_start

Evaluatable

Yes

# Specify magnetization inductance state by — option for setting the initial state
Current | Magnetic flux

Details

The option to set the initial state. Defined as:

  • Current - setting the initial state of the transformer by the initial current through the transformer. This option is used by default.

  • Magnetic flux - setting the initial state of the transformer by magnetic flux.

Dependencies

To use this parameter, set the parameters Magnetization inductance parameterized by to . Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Values

Current | Magnetic flux

Default value

Current

Program usage name

saturation_start_option

Evaluatable

No

# Magnetization inductance current — initial magnetising inductance current
A | MA | kA | mA | nA | pA | uA

Details

The initial current value used to calculate the magnetic flux value at zero time. This is the current flowing through the magnetising inductance of the transformer. The total magnetising current consists of the current through the active magnetising resistance and the current through the magnetising inductance.

Dependencies

This parameter is only used when selecting the value Current for the parameter Specify magnetization inductance state by.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_Lm_start

Evaluatable

Yes

# Magnetization inductance magnetic flux — initial magnetic flux of the magnetising inductance
Wb | N*m/A | mN*m/A

Details

The value of the magnetic flux at zero time.

Dependencies

This parameter is only used when selecting the value Magnetic flux for the parameter Specify magnetization inductance state by.

Units

Wb | N*m/A | mN*m/A

Default value

0.0 Wb

Program usage name

Phi_start

Evaluatable

Yes

# Magnetization inductance magnetic flux density — initial magnetic induction of the magnetising inductance
G | T

Details

The value of magnetic induction at zero time.

Dependencies

This parameter is used when the parameter Magnetization inductance parameterized by is set to . Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

G | T

Default value

0.0 T

Program usage name

B_start

Evaluatable

Yes

# Magnetization inductance field strength — initial field strength of magnetising inductance
A/m

Details

The value of the magnetic field strength at zero time.

Dependencies

This parameter is used when the parameter Magnetization inductance parameterized by is set to . Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

A/m

Default value

0.0 A/m

Program usage name

H_start

Evaluatable

Yes

# Second winding burden inductance initial current — initial load inductance current of the second winding
A | MA | kA | mA | nA | pA | uA

Details

Initial load inductance current of the second winding.

Dependencies

To use this parameter, select the checkbox Include burden, and for the parameter Burden type set the value to L or Series RL.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_L_burden2_start

Evaluatable

Yes

# Third winding burden inductance initial current — initial load inductance current of the third winding
A | MA | kA | mA | nA | pA | uA

Details

Initial load inductance current of the third winding.

Dependencies

To use this parameters:

  • select the check box Include burden;

  • set the Burden type parameters to L or Series RL;

  • set the Number of windings parameters to Three, Four, Five or Six.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_L_burden3_start

Evaluatable

Yes

# Fourth winding burden inductance initial current — initial load inductance current of the fourth winding
A | MA | kA | mA | nA | pA | uA

Details

Initial load inductance current of the fourth winding.

Dependencies

To use this parameters:

  • select the check box Include burden;

  • set the Burden type parameters to L or Series RL;

  • set the Number of windings parameters to Four, Five or Six.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_L_burden4_start

Evaluatable

Yes

# Fifth winding burden inductance initial current — initial load inductance current of the fifth winding
A | MA | kA | mA | nA | pA | uA

Details

Initial load inductance current of the fifth winding.

Dependencies

To use this parameters:

  • select the check box Include burden;

  • set the Burden type parameters to L or Series RL;

  • set the Number of windings parameters to Five or Six.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_L_burden5_start

Evaluatable

Yes

# Sixth winding burden inductance initial current — initial load inductance current of the sixth winding
A | MA | kA | mA | nA | pA | uA

Details

Initial load inductance current of the sixth winding.

Dependencies

To use this parameters:

  • select the check box Include burden;

  • set the Burden type parameters to L or Series RL;

  • set the Number of windings parameters to Six.

Units

A | MA | kA | mA | nA | pA | uA

Default value

0.0 A

Program usage name

i_L_burden6_start

Evaluatable

Yes

Parasitic

# Combined leakage inductance parasitic parallel conductance — parasitic parallel conductance of the total scattering inductance
S | mS | nS | uS | 1/Ohm

Details

This parameters is used to represent small parasitic effects in parallel to the aggregate scattering inductance. The small parallel conductance may be required for modelling some circuit topologies.

Dependencies

To use this parameter, set the parameter Winding parameterized by to the value of Combined primary and secondary values.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_Leq

Evaluatable

Yes

# First leakage inductance parasitic parallel conductance — parasitic parallel conductance of the first winding scattering inductance
S | mS | nS | uS | 1/Ohm

Details

This parameter is used to represent small parasitic effects in parallel with the scattering inductance on the first winding. The small parallel conductance may be required for modelling some circuit topologies.

Dependencies

To use this parameter, set the Winding parameterized by parameters to Separate primary and secondary values or set the Number of windings parameters to . Three, Four, Five or Six.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L1

Evaluatable

Yes

# Second leakage inductance parasitic parallel conductance — parasitic parallel conductance of the second winding scattering inductance
S | mS | nS | uS | 1/Ohm

Details

This parameter is used to represent small parasitic effects parallel to the scattering inductance on the second winding.

Dependencies

To use this parameter, set the Winding parameterized by parameters to the value of Separate primary and secondary values or set the Number of windings parameters to. Three, Four, Five or Six.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L2

Evaluatable

Yes

# Third leakage inductance parasitic parallel conductance — parasitic parallel conductance of the third winding scattering inductance
S | mS | nS | uS | 1/Ohm

Details

This parameter is used to represent small parasitic effects in parallel to the scattering inductance on the third winding.

Dependencies

To use this parameter, set the parameter Number of windings to . Three, Four, Five or Six.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L3

Evaluatable

Yes

# Fourth leakage inductance parasitic parallel conductance — parasitic parallel conductance of the fourth winding scattering inductance
S | mS | nS | uS | 1/Ohm

Details

This parameter is used to represent small parasitic effects parallel to the scattering inductance on the fourth winding.

Dependencies

To use this parameter, set the parameter Number of windings to . Four, Five or Six.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L4

Evaluatable

Yes

# Fifth leakage inductance parasitic parallel conductance — parasitic parallel conductance of the fifth winding scattering inductance
S | mS | nS | uS | 1/Ohm

Details

This parameter is used to represent small parasitic effects parallel to the fifth winding scattering inductance.

Dependencies

To use this parameter, set the parameters Number of windings to Five or Six.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L5

Evaluatable

Yes

# Sixth leakage inductance parasitic parallel conductance — parasitic parallel conductance of the sixth winding scattering inductance
S | mS | nS | uS | 1/Ohm

Details

This parameter is used to represent small parasitic effects parallel to the scattering inductance on the sixth winding.

Dependencies

To use this parameter, set the parameters Number of windings to . Six.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L6

Evaluatable

Yes

# Second winding burden inductance parasitic parallel conductance — parasitic parallel conductance of the load inductance of the second winding
S | mS | nS | uS | 1/Ohm

Details

Parasitic parallel conductance of the load inductance of the second winding.

Dependencies

To use this parameters, tick the checkbox Include burden.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L_burden2

Evaluatable

Yes

# Third winding burden inductance parasitic parallel conductance — parasitic parallel conductance of the load inductance of the third winding
S | mS | nS | uS | 1/Ohm

Details

Parasitic parallel conductance of the third winding load inductance.

Dependencies

To use this parameter, select the Include burden checkbox and set the Number of windings parameters to Three, Four, Five or Six.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L_burden3

Evaluatable

Yes

# Fourth winding burden inductance parasitic parallel conductance — parasitic parallel conductance of the fourth winding load inductance
S | mS | nS | uS | 1/Ohm

Details

Parasitic parallel conductance of the fourth winding load inductance.

Dependencies

To use this parameter, select the checkbox Include burden, and set the parameters Number of windings to a value of Four, Five or Six.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L_burden4

Evaluatable

Yes

# Fifth winding burden inductance parasitic parallel conductance — parasitic parallel conductance of the fifth winding load inductance
S | mS | nS | uS | 1/Ohm

Details

Parasitic parallel conductance of the fifth winding load inductance.

Dependencies

To use this parameter, tick the checkbox Include burden, and for the parameter Number of windings set the value to Five or Six.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L_burden5

Evaluatable

Yes

# Sixth winding burden inductance parasitic parallel conductance — parasitic parallel conductance of the sixth winding load inductance
S | mS | nS | uS | 1/Ohm

Details

Parasitic parallel conductance of the load inductance of the sixth winding.

Dependencies

To use this parameter, select the checkbox Include burden, and set the parameters Number of windings to the value of Six.

Units

S | mS | nS | uS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L_burden6

Evaluatable

Yes