Voltage Transformer

Voltage transformer (TN).

blockType: AcausalElectricPowerSystems.Passive.Transformers.Voltage

Path in the library:

/Physical Modeling/Electrical/Passive/Transformers/Voltage Transformer

Description

Block Voltage Transformer It is a multi-winding transformer that can be modeled as a voltage transformer with various levels of nonlinearity.

Parameter Group Initial Conditions It is used to set the initial current or flow for each of the inductors, as well as for the load inductors if the flag is checked. Include burden. Note that these values are not used if in the solver configuration Solver Configuration the flag is selected Start simulation from steady state.

Parameter Group Parasitic it represents small parasitic effects. Small parallel conductivities may be required to model some circuit topologies.

For more information about the equations and modes implemented in the block, see Nonlinear Transformer.

Ports

Conserving

# 1+ — positive terminal of the first winding
electricity

Details

Electrical port, represents the terminal of the first winding with positive polarity.

Program usage name

p1

# 1- — negative terminal of the first winding
electricity

Details

Electrical port, represents the terminal of the first winding with negative polarity.

Program usage name

n1

# 2+ — positive terminal of the second winding
electricity

Details

Electricity port, represents the terminal of the second winding with positive polarity.

Dependencies

To use this port, uncheck Include burden.

Program usage name

p2

# 2- — negative terminal of the second winding
electricity

Details

Electricity port, represents the terminal of the second winding with negative polarity.

Dependencies

To use this port, uncheck Include burden.

Program usage name

n2

# 3+ — positive terminal of the third winding
electricity

Details

Electricity port, represents the terminal of the third winding with positive polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings value. Three, Four, Five or Six.

Program usage name

p3

# 3- — negative terminal of the third winding
electricity

Details

Electricity port, represents the terminal of the third winding with negative polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings value. Three, Four, Five or Six.

Program usage name

n3

# 4+ — positive terminal of the fourth winding
electricity

Details

Electricity port, represents the terminal of the fourth winding with positive polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings value. Four, Five or Six.

Program usage name

p4

# 4- — negative terminal of the fourth winding
electricity

Details

Electricity port, represents the terminal of the fourth winding with negative polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings value. Four, Five or Six.

Program usage name

n4

# 5+ — positive terminal of the fifth winding
electricity

Details

Electricity port, represents the terminal of the fifth winding with positive polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings the value of Five or Six.

Program usage name

p5

# 5- — negative terminal of the fifth winding
electricity

Details

Electricity port, represents the terminal of the fifth winding with negative polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings the value of Five or Six.

Program usage name

n5

# 6+ — positive terminal of the sixth winding
electricity

Details

Electricity port, represents the terminal of the sixth winding with positive polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings the value of Six.

Program usage name

p6

# 6- — negative terminal of the sixth winding
electricity

Details

Electricity port, represents the terminal of the sixth winding with negative polarity.

Dependencies

To use this port, uncheck Include burden, and for the parameters Number of windings the value of Six.

Program usage name

n6

Output

# v2 — second winding voltage
scalar

Details

Voltage of the second winding.

Dependencies

To use this port, select the checkbox Include burden.

Data types

Float64.

Complex numbers support

No

# v3 — voltage of the third winding.
scalar

Details

Voltage of the third winding.

Dependencies

To use this port, select the checkbox Include burden, and set the value for the parameters Number of windings. Three, Four, Five or Six.

Data types

Float64.

Complex numbers support

No

# v4 — fourth winding voltage
scalar

Details

Voltage of the fourth winding.

Dependencies

To use this port, select the checkbox Include burden, and set the value for the parameters Number of windings to . Four, Five or Six.

Data types

Float64.

Complex numbers support

No

# v5 — fifth winding voltage
scalar

Details

Voltage of the fifth winding.

Dependencies

To use this port, select the checkbox Include burden, and set the parameters Number of windings to the value of Five or Six.

Data types

Float64.

Complex numbers support

No

# v6 — sixth winding voltage
scalar

Details

Voltage of the sixth winding.

Dependencies

To use this port, select the checkbox Include burden, and set the parameters Number of windings to a value of Six.

Data types

Float64.

Complex numbers support

No

Parameters

Main

# Number of windings — switching between two-, three-, four-, five- and six-winding transformers
Two | Three | Four | Five | Six

Details

Switching between two-, three-, four-, five- and six-winding transformers.

  • Two — the unit simulates a two-winding transformer.

  • Three — the unit simulates a three-winding transformer.

  • Four — the unit simulates a four-winding transformer.

  • Five — the block simulates a five-winding transformer.

  • Six — the unit simulates a six-winding transformer.

Values

Two | Three | Four | Five | Six

Default value

Two

Program usage name

N_windings

Evaluatable

No

# Turns ratio parameterization by — the option of setting the transformation coefficient TN
Number of turns

Details

Choose one of the following methods for setting the TN transformation coefficient:

  • Number of turns — through the number of turns.

Values

Number of turns

Default value

Number of turns

Program usage name

turns_ratio_parameterization

Evaluatable

No

# First winding number of turns — number of turns of the first winding

Details

The number of turns of the wire of the first transformer winding.

Dependencies

To use this parameter, set for the parameter Turns ratio parameterization by meaning Number of turns.

Default value

220

Program usage name

N_1

Evaluatable

Yes

# Second winding number of turns — number of turns of the second winding

Details

The number of turns of the wire of the second transformer winding.

Dependencies

To use this parameter, set for the parameter Turns ratio parameterization by meaning Number of turns.

Default value

100

Program usage name

N_2

Evaluatable

Yes

# Third winding number of turns — number of turns of the third winding

Details

The number of turns of the wire of the third transformer winding.

Dependencies

To use this parameter, set for the parameter Turns ratio parameterization by meaning Number of turns, and for the parameter Number of windings meaning Three, Four, Five or Six.

Default value

100

Program usage name

N_3

Evaluatable

Yes

# Fourth winding number of turns — number of turns of the fourth winding

Details

The number of turns of the wire of the fourth transformer winding.

Dependencies

To use this parameter, set for the parameter Turns ratio parameterization by meaning Number of turns, and for the parameter Number of windings meaning Four, Five or Six.

Default value

100

Program usage name

N_4

Evaluatable

Yes

# Fifth winding number of turns — number of turns of the fifth winding

Details

The number of turns of the wire of the fifth transformer winding.

Dependencies

To use this parameter, set for the parameter Turns ratio parameterization by meaning Number of turns, and for the parameter Number of windings meaning Five or Six.

Default value

100

Program usage name

N_5

Evaluatable

Yes

# Sixth winding number of turns — number of turns of the sixth winding

Details

The number of turns of the wire of the sixth transformer winding.

Dependencies

To use this parameter, set for the parameter Turns ratio parameterization by meaning Number of turns, and for the parameter Number of windings meaning Six.

Default value

100

Program usage name

N_6

Evaluatable

Yes

# Winding parameterized by — type of windings scattering representation
Combined primary and secondary values | Separate primary and secondary values

Details

The method of scattering in the winding. Set as:

  • Combined primary and secondary values — use concentrated resistance and inductance values representing the cumulative leakage in the first and secondary windings.;

  • Separate primary and secondary values — use separate resistances and inductors to represent leaks in the first and secondary windings.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Two.

Values

Combined primary and secondary values | Separate primary and secondary values

Default value

Combined primary and secondary values

Program usage name

winding_parameterization

Evaluatable

No

# Combined winding resistance — total active resistance of the windings
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The concentrated equivalent active resistance is Req, which represents the combined power losses of the first and second windings.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Combined primary and secondary values.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

0.01 Ohm

Program usage name

R_eq

Evaluatable

Yes

# Combined leakage inductance — cumulative scattering inductance
H | nH | uH | mH

Details

The concentrated equivalent inductance is Leq, which represents the combined magnetic flux losses of the first and second windings.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Combined primary and secondary values.

Units

H | nH | uH | mH

Default value

0.0001 H

Program usage name

L_eq

Evaluatable

Yes

# First winding resistance — active resistance of the first winding
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active resistance is R1, which represents the power loss of the first winding.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Separate primary and secondary values or set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

5.0 Ohm

Program usage name

R_1

Evaluatable

Yes

# First leakage inductance — scattering inductance of the first winding
H | nH | uH | mH

Details

The inductance is L1, which represents the magnetic flux loss of the first winding.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Separate primary and secondary values or set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

H | nH | uH | mH

Default value

0.0001 H

Program usage name

L_1

Evaluatable

Yes

# Second winding resistance — active resistance of the second winding
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active resistance is R2, which represents the power loss of the second winding.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Separate primary and secondary values or set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

5.0 Ohm

Program usage name

R_2

Evaluatable

Yes

# Second leakage inductance — scattering inductance of the second winding
H | nH | uH | mH

Details

The inductance is L2, which represents the magnetic flux loss of the second winding.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Separate primary and secondary values or set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

H | nH | uH | mH

Default value

0.0001 H

Program usage name

L_2

Evaluatable

Yes

# Third winding resistance — active resistance of the third winding
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active resistance is R3, which represents the power loss of the third winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

5.0 Ohm

Program usage name

R_3

Evaluatable

Yes

# Third leakage inductance — scattering inductance of the third winding
H | nH | uH | mH

Details

The inductance is L3, which represents the magnetic flux loss of the third winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

H | nH | uH | mH

Default value

0.0001 H

Program usage name

L_3

Evaluatable

Yes

# Fourth winding resistance — active resistance of the fourth winding
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active resistance is R4, which represents the power loss of the fourth winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Four, Five or Six.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

5.0 Ohm

Program usage name

R_4

Evaluatable

Yes

# Fourth leakage inductance — the scattering inductance of the fourth winding
H | nH | uH | mH

Details

The inductance is L4, which represents the magnetic flux loss of the fourth winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Four, Five or Six.

Units

H | nH | uH | mH

Default value

0.0001 H

Program usage name

L_4

Evaluatable

Yes

# Fifth winding resistance — active resistance of the fifth winding
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active resistance is R5, which represents the power loss of the fifth winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Five or Six.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

5.0 Ohm

Program usage name

R_5

Evaluatable

Yes

# Fifth leakage inductance — fifth winding scattering inductance
H | nH | uH | mH

Details

The inductance is L5, which represents the magnetic flux loss of the fifth winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Five or Six.

Units

H | nH | uH | mH

Default value

0.0001 H

Program usage name

L_5

Evaluatable

Yes

# Sixth winding resistance — active resistance of the sixth winding
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active resistance is R6, which represents the power loss of the sixth winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Six.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

5.0 Ohm

Program usage name

R_6

Evaluatable

Yes

# Sixth leakage inductance — scattering inductance of the sixth winding
H | nH | uH | mH

Details

The inductance is L6, which represents the magnetic flux loss of the sixth winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Six.

Units

H | nH | uH | mH

Default value

0.0001 H

Program usage name

L_6

Evaluatable

Yes

Magnetization

# Magnetization resistance — active magnetization resistance
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active resistance is Rm, representing the magnetic losses in the transformer core.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

100.0 Ohm

Program usage name

R_m

Evaluatable

Yes

# Magnetization inductance parameterized by — parameterization of the block
Single inductance (linear) | Single saturation point | Magnetic flux versus current characteristic | Magnetic flux density versus magnetic field strength characteristic | Magnetic flux density versus magnetic field strength characteristic with hysteresis | Voltage versus current characteristic

Details

The block parameterization method. Set as:

  • Single inductance (linear) — the values of the number of turns, unsaturated and saturated inductors, saturation magnetic flux and parasitic parallel conductivity are indicated. This option is used by default.

  • Single saturation point — the values of the number of turns, unsaturated inductance and parasitic parallel conductivity are indicated.

  • Magnetic flux versus current characteristic — in addition to the number of turns and the value of the parasitic parallel conductivity, the current vector and the magnetic flux vector are indicated to fill in the table of the dependence of the magnetic flux on the current.

  • Magnetic flux density versus magnetic field strength characteristic — in addition to the number of turns and the value of parasitic parallel conductivity, the values of the effective length and cross-sectional area of the core, as well as the vector of magnetic field strength and the vector of magnetic induction are indicated to fill in the table of dependence of magnetic induction on magnetic field strength.

  • Magnetic flux density versus magnetic field strength characteristic with hysteresis — in addition to the number of turns, the effective length and the cross-sectional area of the core, the values of the initial derivative of the anhysteresis curve B-H, magnetic induction and field strength at a certain point of the curve B-H are indicated, as well as the coefficient of reversible magnetization, the volume coupling coefficient and the inter-domain coupling coefficient for determining magnetic induction depending on the current value and history changes in magnetic field strength.

  • Voltage versus current characteristic — setting saturation via the volt-ampere characteristic (VAC).

Values

Single inductance (linear) | Single saturation point | Magnetic flux versus current characteristic | Magnetic flux density versus magnetic field strength characteristic | Magnetic flux density versus magnetic field strength characteristic with hysteresis | Voltage versus current characteristic

Default value

Voltage versus current characteristic

Program usage name

saturation_parameterization

Evaluatable

No

# Magnetic field strength vector, H — vector of magnetic field strength values
A/m

Details

The values of the magnetic field strength used to fill in the table of the dependence of magnetic induction on the magnetic field strength.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux versus current characteristic.

Units

A/m

Default value

[0.0, 200.0, 400.0, 600.0, 800.0, 1000.0] A/m

Program usage name

H_vector

Evaluatable

Yes

# Magnetic flux density vector, B — vector of magnetic induction values
T | nT | uT | mT | G

Details

The values of magnetic induction used to fill in the table of dependence of magnetic induction on the strength of the magnetic field.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux versus current characteristic.

Units

T | nT | uT | mT | G

Default value

[0.0, 0.81, 1.25, 1.42, 1.48, 1.49] T

Program usage name

B_vector

Evaluatable

Yes

# Effective length — effective core length
m | um | mm | cm | km | in | ft | yd | mi | nmi

Details

The effective length of the core, i.e. the average length of the magnetic flux path.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux density versus magnetic field strength characteristic or Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

m | um | mm | cm | km | in | ft | yd | mi | nmi

Default value

0.2 m

Program usage name

effective_length

Evaluatable

Yes

# Effective cross-sectional area — effective cross-sectional area
m^2 | um^2 | mm^2 | cm^2 | km^2 | in^2 | ft^2 | yd^2 | mi^2 | ha | ac

Details

The effective cross-sectional area of the core, i.e. the average area of the magnetic flux path.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux density versus magnetic field strength characteristic or Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

m^2 | um^2 | mm^2 | cm^2 | km^2 | in^2 | ft^2 | yd^2 | mi^2 | ha | ac

Default value

2e-4 m^2

Program usage name

A_effective

Evaluatable

Yes

# Unsaturated inductance — unsaturated inductance
H | nH | uH | mH

Details

The value of the inductance used when the transformer is operating in the linear domain.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Single inductance (linear) or Single saturation point.

Units

H | nH | uH | mH

Default value

4e-2 H

Program usage name

L_m

Evaluatable

Yes

# Saturated inductance — saturated inductance
H | nH | uH | mH

Details

The value of the inductance used when the transformer is operating in the saturation zone.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Single saturation point.

Units

H | nH | uH | mH

Default value

1e-2 H

Program usage name

L_m_sat

Evaluatable

Yes

# Current vector, i — vector of current values
A | pA | nA | uA | mA | kA | MA

Details

The current values used to fill in the table of magnetic flux versus current.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux versus current characteristic.

Units

A | pA | nA | uA | mA | kA | MA

Default value

[0.0, 0.4, 0.8, 1.2, 1.6, 2.0] A

Program usage name

i_vector

Evaluatable

Yes

# Magnetic flux vector, Φ — vector of magnetic flux values
Wb | mN*m/A | N*m/A | kN*m/A | kgf*m/A

Details

The values of the magnetic flux used to fill in the table of the dependence of the magnetic flux on the current.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux versus current characteristic.

Units

Wb | mN*m/A | N*m/A | kN*m/A | kgf*m/A

Default value

[0.0, 0.161, 0.25, 0.284, 0.295, 0.299] * 1e-3 Wb

Program usage name

Phi_vector

Evaluatable

Yes

# Current vector for V-I option, (secondary side - RMS) — vector of effective values of the VAC current
A | pA | nA | uA | mA | kA | MA

Details

The vector of the effective values of the VAC current.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Voltage versus current characteristic.

Units

A | pA | nA | uA | mA | kA | MA

Default value

[0.0, 0.1414, 0.2828, 0.4243, 0.5657, 0.7071] A

Program usage name

I_RMS_vector

Evaluatable

Yes

# Voltage vector for V-I option, (secondary side - RMS) — the vector of effective voltage values of the VAC
V | uV | mV | kV | MV

Details

The vector of the effective voltage values of the VAC.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Voltage versus current characteristic.

Units

V | uV | mV | kV | MV

Default value

[0.0, 7.1530, 11.1072, 12.6178, 13.1065, 13.2842] V

Program usage name

V_RMS_vector

Evaluatable

Yes

# System frequency — network frequency
Hz | kHz | MHz | GHz

Details

Network frequency.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Voltage versus current characteristic.

Units

Hz | kHz | MHz | GHz

Default value

50.0 Hz

Program usage name

f

Evaluatable

Yes

# Saturation magnetic flux — saturated magnetic flux
Wb | mN*m/A | N*m/A | kN*m/A | kgf*m/A

Details

The value of the magnetic flux at which the transformer is saturated.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Single saturation point.

Units

Wb | mN*m/A | N*m/A | kN*m/A | kgf*m/A

Default value

0.00016 Wb

Program usage name

Phi_sat

Evaluatable

Yes

# Anhysteretic B-H gradient when H is zero — derivative of the anhysteresis curve B-H near zero field strength
H/m | mH/m | nH/m | uH/m | H/km | mH/km | T*m/A

Details

The derivative of the anhysteretic (without hysteresis) B-H curve is near zero field strength. It is set as the average value of the derivative of the positive and negative hysteresis curves.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

H/m | mH/m | nH/m | uH/m | H/km | mH/km | T*m/A

Default value

0.005 T*m/A

Program usage name

dB_dH_0

Evaluatable

Yes

# Flux density point on anhysteretic B-H curve — the value of magnetic induction at a point on the anhysteresis curve B-H
T | nT | uT | mT | G

Details

Specify the value of the magnetic induction at a point on the anhysteresis curve. The most accurate option is to select a point at high field strength, when the positive and negative hysteresis curves coincide.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

T | nT | uT | mT | G

Default value

1.49 T

Program usage name

B_anhysteretic

Evaluatable

Yes

# Corresponding field strength — appropriate field strength
A/m

Details

The corresponding field strength for the point specified by the parameter Flux density point on anhysteretic B-H curve.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

A/m

Default value

1000.0 A/m

Program usage name

H_anhysteretic

Evaluatable

Yes

# Coefficient for reversible magnetization, c — coefficient of reversible magnetization

Details

The proportion of magnetization that is reversible. The value must be greater than zero and less than one.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Default value

0.1

Program usage name

c

Evaluatable

Yes

# Bulk coupling coefficient, K — volumetric coupling coefficient
A/m

Details

A parameter of the Giles—Atherton model, which primarily determines the magnitude of the field strength at which the B-H curve intersects the line of zero magnetic induction.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

A/m

Default value

200.0 A/m

Program usage name

K

Evaluatable

Yes

# Inter-domain coupling factor, α — the coefficient of inter-domain communication

Details

The Giles—Atherton parameter, which primarily affects the intersection points of the B-H curves with the zero field strength line. Typical values range from 1e−4 before 1e−3.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Default value

1e-4

Program usage name

alpha

Evaluatable

Yes

# Interpolation option — the interpolation option
Linear | Smooth

Details

The option to interpolate the search table. Set as:

  • Linear — Choose this option to get the best performance.;

  • Smooth — select this option to obtain a continuous curve with continuous first-order derivatives.

Values

Linear | Smooth

Default value

Linear

Program usage name

interpolation_option

Evaluatable

No

Burden

# Include burden — load of secondary windings TN

Details

If this option is selected, an internal load is connected to the secondary windings, and the output ports will change from electric to directional (scalars).

Default value

false (switched off)

Program usage name

include_burden

Evaluatable

No

# Burden type — type of load
R | L | Series RL

Details

Type of load:

  • R — active;

  • L — inductive;

  • Series RL — sequential active-inductive.

Dependencies

To use this option, check the box Include burden.

Values

R | L | Series RL

Default value

R

Program usage name

burden_type

Evaluatable

No

# Second winding burden resistance — active load resistance of the second winding
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active load resistance of the second winding.

Dependencies

To use this option, check the box Include burden, and for the parameter Burden type set the value R or Series RL.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

5.0 Ohm

Program usage name

R_burden2

Evaluatable

Yes

# Second winding burden inductance — load inductance of the second winding
H | nH | uH | mH

Details

Load inductance of the second winding.

Dependencies

To use this option, check the box Include burden,and for the parameter Burden type set the value L or Series RL.

Units

H | nH | uH | mH

Default value

0.001 H

Program usage name

L_burden2

Evaluatable

Yes

# Third winding burden resistance — active load resistance of the third winding
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active load resistance of the third winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning R or Series RL;

  • set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

5.0 Ohm

Program usage name

R_burden3

Evaluatable

Yes

# Third winding burden inductance — load inductance of the third winding
H | nH | uH | mH

Details

Load inductance of the third winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning L or Series RL;

  • set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

H | nH | uH | mH

Default value

0.001 H

Program usage name

L_burden3

Evaluatable

Yes

# Fourth winding burden resistance — active load resistance of the fourth winding
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active load resistance of the fourth winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning R or Series RL;

  • set for the parameter Number of windings meaning Four, Five or Six.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

5.0 Ohm

Program usage name

R_burden4

Evaluatable

Yes

# Fourth winding burden inductance — load inductance of the fourth winding
H | nH | uH | mH

Details

Load inductance of the fourth winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning L or Series RL;

  • set for the parameter Number of windings meaning Four, Five or Six.

Units

H | nH | uH | mH

Default value

0.001 H

Program usage name

L_burden4

Evaluatable

Yes

# Fifth winding burden resistance — active load resistance of the fifth winding
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active load resistance of the fifth winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning R or Series RL;

  • set for the parameter Number of windings meaning Five or Six.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

5.0 Ohm

Program usage name

R_burden5

Evaluatable

Yes

# Fifth winding burden inductance — load inductance of the fifth winding
H | nH | uH | mH

Details

Load inductance of the fifth winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning L or Series RL;

  • set for the parameter Number of windings meaning Five or Six.

Units

H | nH | uH | mH

Default value

0.001 H

Program usage name

L_burden5

Evaluatable

Yes

# Sixth winding burden resistance — active load resistance of the sixth winding
Ohm | mOhm | kOhm | MOhm | GOhm

Details

The active load resistance of the sixth winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning R or Series RL;

  • set for the parameter Number of windings meaning Six.

Units

Ohm | mOhm | kOhm | MOhm | GOhm

Default value

5.0 Ohm

Program usage name

R_burden6

Evaluatable

Yes

# Sixth winding burden inductance — load inductance of the sixth winding
H | nH | uH | mH

Details

Load inductance of the sixth winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning L or Series RL;

  • set for the parameter Number of windings meaning Six.

Units

H | nH | uH | mH

Default value

0.001 H

Program usage name

L_burden6

Evaluatable

Yes

Initial Conditions

# Combined leakage current — the initial current of the cumulative scattering inductance
A | pA | nA | uA | mA | kA | MA

Details

The initial value of the cumulative scattering inductance current.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Combined primary and secondary values.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_Leq_start

Evaluatable

Yes

# First leakage inductance current — the initial current of the scattering inductance of the first winding
A | pA | nA | uA | mA | kA | MA

Details

The initial value of the scattering inductance current of the first transformer winding.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Separate primary and secondary values or set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_L1_start

Evaluatable

Yes

# Second leakage inductance current — the initial current of the scattering inductance of the second winding
A | pA | nA | uA | mA | kA | MA

Details

The initial value of the scattering inductance current of the second transformer winding.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Separate primary and secondary values or set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_L2_start

Evaluatable

Yes

# Third leakage inductance current — the initial current of the scattering inductance of the third winding
A | pA | nA | uA | mA | kA | MA

Details

The initial value of the scattering inductance current of the third transformer winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_L3_start

Evaluatable

Yes

# Fourth leakage inductance current — the initial leakage inductance current of the fourth winding
A | pA | nA | uA | mA | kA | MA

Details

The initial value of the scattering inductance current of the fourth transformer winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Four, Five or Six.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_L4_start

Evaluatable

Yes

# Fifth leakage inductance current — the initial current of the fifth winding scattering inductance
A | pA | nA | uA | mA | kA | MA

Details

The initial value of the scattering inductance current of the fifth transformer winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Five or Six.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_L5_start

Evaluatable

Yes

# Sixth leakage inductance current — the initial current of the scattering inductance of the sixth winding
A | pA | nA | uA | mA | kA | MA

Details

The initial value of the scattering inductance current of the sixth transformer winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Six.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_L6_start

Evaluatable

Yes

# Specify magnetization inductance state by — the option to set the initial state
Current | Magnetic flux

Details

The option to set the initial state. Set as:

  • Current — setting the initial state of the transformer based on the initial current through the transformer. This option is used by default.;

  • Magnetic flux — setting the initial state of the transformer by magnetic flux.

Dependencies

To use this parameter, set for the parameter Magnetization inductance parameterized by meaning Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Values

Current | Magnetic flux

Default value

Current

Program usage name

saturation_start_option

Evaluatable

No

# Magnetization inductance current — initial magnetization inductance current
A | pA | nA | uA | mA | kA | MA

Details

The initial value of the current used to calculate the value of the magnetic flux at time zero. This is the current passing through the magnetization inductance of the transformer. The total magnetization current consists of the current passing through the active magnetization resistance and the current passing through the magnetization inductance.

Dependencies

This parameter is used only when selecting a value. Current for the parameter Specify magnetization inductance state by.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_Lm_start

Evaluatable

Yes

# Magnetization inductance magnetic flux — the initial magnetic flux of the magnetization inductance
Wb | mN*m/A | N*m/A | kN*m/A | kgf*m/A

Details

The value of the magnetic flux at time zero.

Dependencies

This parameter is used only when selecting a value. Magnetic flux for the parameter Specify magnetization inductance state by.

Units

Wb | mN*m/A | N*m/A | kN*m/A | kgf*m/A

Default value

0.0 Wb

Program usage name

Phi_start

Evaluatable

Yes

# Magnetization inductance magnetic flux density — initial magnetic induction of the magnetization inductance
T | nT | uT | mT | G

Details

The value of magnetic induction at time zero.

Dependencies

This parameter is used if for the parameter Magnetization inductance parameterized by value selected Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

T | nT | uT | mT | G

Default value

0.0 T

Program usage name

B_start

Evaluatable

Yes

# Magnetization inductance field strength — initial field strength of the magnetization inductance
A/m

Details

The value of the magnetic field strength at time zero.

Dependencies

This parameter is used if for the parameter Magnetization inductance parameterized by value selected Magnetic flux density versus magnetic field strength characteristic with hysteresis.

Units

A/m

Default value

0.0 A/m

Program usage name

H_start

Evaluatable

Yes

# Second winding burden inductance initial current — initial load inductance current of the second winding
A | pA | nA | uA | mA | kA | MA

Details

The initial load inductance current of the second winding.

Dependencies

To use this option, check the box Include burden, and for the parameter Burden type set the value L or Series RL.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_L_burden2_start

Evaluatable

Yes

# Third winding burden inductance initial current — initial load inductance current of the third winding
A | pA | nA | uA | mA | kA | MA

Details

The initial load inductance current of the third winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning L or Series RL;

  • set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_L_burden3_start

Evaluatable

Yes

# Fourth winding burden inductance initial current — the initial load inductance current of the fourth winding
A | pA | nA | uA | mA | kA | MA

Details

The initial load inductance current of the fourth winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning L or Series RL;

  • set for the parameter Number of windings meaning Four, Five or Six.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_L_burden4_start

Evaluatable

Yes

# Fifth winding burden inductance initial current — initial load inductance current of the fifth winding
A | pA | nA | uA | mA | kA | MA

Details

The initial load inductance current of the fifth winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning L or Series RL;

  • set for the parameter Number of windings meaning Five or Six.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_L_burden5_start

Evaluatable

Yes

# Sixth winding burden inductance initial current — the initial load inductance current of the sixth winding
A | pA | nA | uA | mA | kA | MA

Details

The initial load inductance current of the sixth winding.

Dependencies

To use this parameter:

  • check the box Include burden;

  • set for the parameter Burden type meaning L or Series RL;

  • set for the parameter Number of windings meaning Six.

Units

A | pA | nA | uA | mA | kA | MA

Default value

0.0 A

Program usage name

i_L_burden6_start

Evaluatable

Yes

Parasitic

# Combined leakage inductance parasitic parallel conductance — parasitic parallel conductivity of the total scattering inductance
S | nS | uS | mS | 1/Ohm

Details

This parameter is used to represent small spurious effects in parallel with the cumulative scattering inductance. A small amount of parallel conduction may be required to simulate some circuit topologies.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Combined primary and secondary values.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_Leq

Evaluatable

Yes

# First leakage inductance parasitic parallel conductance — parasitic parallel conduction of the scattering inductance of the first winding
S | nS | uS | mS | 1/Ohm

Details

This parameter is used to represent small spurious effects parallel to the scattering inductance on the first winding. A small amount of parallel conduction may be required to simulate some circuit topologies.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Separate primary and secondary values or set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L1

Evaluatable

Yes

# Second leakage inductance parasitic parallel conductance — parasitic parallel conduction of the scattering inductance of the second winding
S | nS | uS | mS | 1/Ohm

Details

This parameter is used to represent small spurious effects in parallel with the scattering inductance on the second winding.

Dependencies

To use this parameter, set for the parameter Winding parameterized by meaning Separate primary and secondary values or set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L2

Evaluatable

Yes

# Third leakage inductance parasitic parallel conductance — parasitic parallel conduction of the scattering inductance of the third winding
S | nS | uS | mS | 1/Ohm

Details

This parameter is used to represent small spurious effects in parallel with the scattering inductance on the third winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Three, Four, Five or Six.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L3

Evaluatable

Yes

# Fourth leakage inductance parasitic parallel conductance — parasitic parallel conduction of the scattering inductance of the fourth winding
S | nS | uS | mS | 1/Ohm

Details

This parameter is used to represent small spurious effects in parallel with the scattering inductance on the fourth winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Four, Five or Six.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L4

Evaluatable

Yes

# Fifth leakage inductance parasitic parallel conductance — parasitic parallel conduction of the fifth winding scattering inductance
S | nS | uS | mS | 1/Ohm

Details

This parameter is used to represent small spurious effects parallel to the scattering inductance on the fifth winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Five or Six.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L5

Evaluatable

Yes

# Sixth leakage inductance parasitic parallel conductance — parasitic parallel conduction of the scattering inductance of the sixth winding
S | nS | uS | mS | 1/Ohm

Details

This parameter is used to represent small spurious effects in parallel with the scattering inductance on the sixth winding.

Dependencies

To use this parameter, set for the parameter Number of windings meaning Six.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L6

Evaluatable

Yes

# Second winding burden inductance parasitic parallel conductance — parasitic parallel conductivity of the load inductance of the second winding
S | nS | uS | mS | 1/Ohm

Details

Parasitic parallel conductivity of the load inductance of the second winding.

Dependencies

To use this option, check the box Include burden.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L_burden2

Evaluatable

Yes

# Third winding burden inductance parasitic parallel conductance — parasitic parallel conductivity of the load inductance of the third winding
S | nS | uS | mS | 1/Ohm

Details

Parasitic parallel conductivity of the load inductance of the third winding.

Dependencies

To use this option, check the box Include burden, and for the parameter Number of windings set the value Three, Four, Five or Six.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L_burden3

Evaluatable

Yes

# Fourth winding burden inductance parasitic parallel conductance — parasitic parallel conductivity of the load inductance of the fourth winding
S | nS | uS | mS | 1/Ohm

Details

Parasitic parallel conductivity of the load inductance of the fourth winding.

Dependencies

To use this option, check the box Include burden, and for the parameter Number of windings set the value Four, Five or Six.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L_burden4

Evaluatable

Yes

# Fifth winding burden inductance parasitic parallel conductance — parasitic parallel conductivity of the load inductance of the fifth winding
S | nS | uS | mS | 1/Ohm

Details

Parasitic parallel conductivity of the load inductance of the fifth winding.

Dependencies

To use this option, check the box Include burden, and for the parameter Number of windings set the value Five or Six.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L_burden5

Evaluatable

Yes

# Sixth winding burden inductance parasitic parallel conductance — parasitic parallel conductivity of the load inductance of the sixth winding
S | nS | uS | mS | 1/Ohm

Details

Parasitic parallel conductivity of the load inductance of the sixth winding.

Dependencies

To use this option, check the box Include burden, and for the parameter Number of windings set the value Six.

Units

S | nS | uS | mS | 1/Ohm

Default value

1e-9 1/Ohm

Program usage name

g_L_burden6

Evaluatable

Yes