Engee documentation

Two-Pulse Gate Multiplexer

Multiplexing input signals to control two power electronic keys in an inverter.

two pulse gate multiplexer

Description

The Two-Pulse Gate Multiplexer unit multiplexes two separate voltage signals into a single vector. The signal converted into a vector can control the gates of two power electronic keys in the converter.

Model

This block can model a two-pulse multiplexer using either the input signal ports or the electrical ports:

  • Input Signal Ports - Two-pulse multiplexer with directional signal ports. Set Gate-control port to `Signal control port' to control the gates of the power electronic keys in the inverter block using voltage control signals.

  • The electrical ports are two-pulse multiplexer with non-directional electrical ports. Set Gate-control port to `Electrical control port' to control the gates of the power electronic keys in the inverter unit.

Ports

Input

G1 - the first signal controlling the gate of the power electronic key
scalar

Port associated with the gate output of the first switching device in the connected inverter unit.

Dependencies

To use this port, set Gate-control port to Signal control port.

G2 is the second signal that controls the gate of the power electronic key
scalar

Port associated with the gate output of the second switching device in the connected inverter unit.

Dependencies

To use this port, set Gate-control port to Signal control port.

Non-directional

G1 is the first electrical signal that controls the gate of the power electrical key
electricity

An electrical non-directional port associated with the gate output of the first switching device in the connected inverter unit.

Dependencies

To use this port, set Gate-control port to `Electrical control port'.

a is the phase A phase AC reference point
`electrical

Electrical non-directional port associated with phase A for the high voltage side of the switching device.

Dependencies

To use this port, set Gate-control port to `Electrical control port'.

G2 is the second electrical signal that controls the gate of the power electrical key
electricity

An electrical non-directional port associated with the gate output of the second switching device in the connected inverter unit.

Dependencies

To use this port, set Gate-control port to `Electrical control port'.

L is a DC reference point
electrical

An electrical non-directional port associated with the negative DC connection of the low voltage side of a switching device.

Dependencies

To use this port, set Gate-control port to `Electrical control port'.

Main

Gate-control port - option for specifying the type of the gate-control port
Signal control port (by default) | Electrical control port

Option to specify the signal input port or the electrical control port.